4-73
Command Usage
• The time acquired from time servers is used to record accurate dates
and times for log events. Without SNTP, the switch only records the
time starting from the factory default set at the last bootup
(e.g., 00:00:00, Jan. 1, 2001).
• This command enables client time requests to time servers specified
via the
sntp servers
command. It issues time synchronization requests
based on the interval set via the
sntp poll
command.
• The SNTP time query method is set to client mode when the first
sntp
client
command is issued. However, if the
sntp broadcast client
command is issued, then the
no sntp broadcast client
command
must be used to return the switch to SNTP client mode.
Example
Related Commands
sntp server (4-71)
sntp poll (4-72)
show sntp (4-73)
show sntp
This command displays the current time and configuration settings for the
SNTP client, and indicates whether or not the local time has been properly
updated.
Console(config)#sntp server 10.1.0.19
Console(config)#sntp poll 60
Console(config)#sntp client
Console(config)#end
Console#show sntp
Current time: Jan 1 02:02:27 2005
Poll interval: 60
Current mode: unicast
SNTP status : Enabled
SNTP server 10.1.0.19 0.0.0.0 0.0.0.0
Current server: 10.1.0.19
Console#
Summary of Contents for 8612T2 - annexe 1
Page 2: ......
Page 23: ...TABLES xix ...
Page 36: ...INTRODUCTION 1 10 ...
Page 50: ...INITIAL CONFIGURATION 2 14 ...
Page 161: ...PORT CONFIGURATION 3 111 Figure 3 48 Port Statistics Continued ...
Page 248: ...CONFIGURING THE SWITCH 3 198 ...
Page 542: ...TROUBLESHOOTING B 2 ...
Page 555: ......