SECURING SHED 

12 

Secure your shed using Treated Timber Pegs or a Bolt Down Kit 

TIMBER PEGS—WOODEN FLOOR 

 

 

The optional Smart Store Timber Peg Down Kit includes six H5 treated 
timber pegs that can be hammered into the ground and then attached to 
the Base Plate with stainless steel screws. A Sentry timber floor can then 
be fitted on top of the Base Plate. 

BOLT DOWN KIT—CONCRETE 

 

 

The optional Smart Store Bolt Down Kit includes 6 x galvanised 
brackets, screws and  dynabolts. 

 

 

Space the brackets evenly around the shed and fix to the Bottom 
Plate and the concrete slab. A 10mm masonry drill bit is required. 

OPTIONAL SENTRY FLOOR 

 

 

Position the Floor Joists centrally between the side 
Base Plates and skew nail each end with two 75mm 
nails. 

 

 

Check that the shed is sitting level and square and 
that the diagonal Bottom Plate measurements are the 
same. 

 

 

Place the floor boards in position and nail securely  

     (6 x 50mm nails per board). 

IMPORTANT—

 

CLEAN UP 

 

REMOVE ALL DRILL FILINGS FROM ROOF, WALLS AND CHANNELS THOROUGHLY. FAILURE TO DO THIS 
WILL RESULT IN CORROSION AND COULD THEREFORE VOID THE WARRANTY

FIT PADBOLT

 

 

 

Rivet Padbolt to door and keeper onto Door Jamb as 
shown. 

YOUR  SMART STORE SHED IS NOW COMPLETE. RELAX

…...

 

FRONT BASE PLATE

 

BACK BASE PLATE

 

JOIST

 

Summary of Contents for SS2010

Page 1: ...ASSEMBLY INSTRUCTIONS SS2010 BASE SIZE 2 020m x 1 020m...

Page 2: ......

Page 3: ...r cladding used in Smart Store Sheds Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as above After a storm wash the cladding and the gutters as s...

Page 4: ...e Flashing 2 050m 1 Door 3 4 Sheet 1 810 m 2 Barge 1 110 m 2 TIMBER Padbolt Support 0 140 m 1 Bottom Plates H4 Green Front Back 2 020 m 2 Spouting 2 050 m 1 Bottom Plates H4 Green Sides 1 020 m 2 HARD...

Page 5: ...late Side Back Wall Sheets Front Wall Sheets Door Jambs Front Wall Sheet Door Sheets Door Side Flashing Padbolt Support Hinge Door Brace Door Top Bottom Channel QUICK OVERVIEW 1 LAY FOUNDATION 2 ASSEM...

Page 6: ...coming through from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bot...

Page 7: ...Rivet sheets together STEP 2 Position door side flash ings and assemble door as shown Drill and rivet as per dia gram ensuring rivets penetrate into door sheet STEP 4 Rivet door brace flashings onto b...

Page 8: ...then nail along the wall sheet to the Top Plate two clouts per pan see fig 1 STEP 4 Nail the wall sheets to the Bottom Plate at each end ensuring each side of wall sheets overhangs the end of Bottom...

Page 9: ...e wall sheets overhang the Top Plate by 15mm as shown Check that the Top Plate is straight then nail wall sheets to the Top Plate using two clouts per pan STEP 4 Nail the wall sheets to the Bottom Pla...

Page 10: ...the Door Jamb Flashing Ensure the door closes properly then fit remaining rivets STEP 3 Place 2 x Wall Sheets on timber Ensure that the top of the sheets are flush with the top of the Top Plate and t...

Page 11: ...panels while they are screwed together Before fixing ensure that the Side Panel overlaps the Back Panel Using 4 x 75mm screws screw the Top Plates together Using 4 x 40mm screws screw the Bot tom Pla...

Page 12: ...ts on both sides The Clear Roof Panel must be secured to the front and back Top Plates Pre drill and fasten with the 40mm weatherseal nails provided SELECT 4 x 1 110 Roof Sheets 1 x 2 050 Spouting 2 x...

Page 13: ...x to the Bottom Plate and the concrete slab A 10mm masonry drill bit is required OPTIONAL SENTRY FLOOR Position the Floor Joists centrally between the side Base Plates and skew nail each end with two...

Page 14: ......

Page 15: ...s less than 200g m2 as published by Branz Warranty certificate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Fast...

Reviews: