background image

 

 

15mm 

15mm 

15mm 

15mm 

ASSEMBLE FRONT PANEL 

BOTTOM PLATE 

1811mm 

1811mm 

TOP PLATE 

530mm

 

960mm

 

TOP PLATE 

DOOR OPENING 

Plan View

 

TOP

 

PLATE

 

DOOR

 

JAMB

 

NAIL

 

x3

 

x3

 

x3

 

SELECT: 

 

2 x 1.850 Wall Sheets 

1 x 2.020 Top Plate (Red) 

1 x 2.020 Bottom Plate (Green) 

2 x 1.850 Door Jamb Flashings 

28 x 30mm Galv Clouts 

17 x Rivets 

STEP 1: 

 

 

Lay out 1 x Top Plate and 1 x Bottom Plate on a flat 
surface as shown  

STEP 2: 

 

 

Using 2 x 30mm clouts, nail the Door Jamb Flashing flush with 
the top of the Top Plate at the correct  measurement as shown 
in plan view. Pre drill holes using a 3.5mm drill bit 

 

 

Check the distance between the top and bottom plates then use 
a further 2 x 30mm clouts to nail the Door Jamb Flashings to 
the bottom Plate. Pre drill holes. 

STEP 4: 

 

 

Place the door on the panel (In open position, approx 5mm 
below top plate). Using two rivets, rivet the top and bottom 
hinges to the Door Jamb Flashing.  

 

 

Ensure the door closes properly, then fit remaining rivets. 

STEP 3: 

 

 

Place 2 x Wall Sheets on timber. 

 

 

Ensure that the top of the sheets are flush with the top of the 
Top Plate and that the sides of the wall sheets overhang the 
Top Plate by 

15mm

 as shown. Nail wall sheets to Top Plate 

(two clouts per pan) 

 

 

Nail the wall sheets to the Bottom Plate making sure that the 
Plates are the correct distance apart and that the sides of the 
wall sheets overhang the Bottom Plate by 

15mm

 

 

Drill & rivet Door Jamb Flashings to wall sheets using four 
rivets equally spaced on each side. 

NOTE: 

The

 

Doorway is standard at 530mm from left-hand end. 

To shift the doorway to the right-hand side of the front 

wall, simply measure 530mm from the right-hand end.

 

NOTE: 

Door can be hinged on either side.

 

IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER 

BASE PLATE –READ THE FOLLOWING; 

 

For sheds with Raised Base Plate option only (see page 5), deduct 

30mm from measurement shown between Top and Bottom Plates on 
all wall panels, so cladding protrudes 20mm below bottom plate

Summary of Contents for SS2010

Page 1: ...ASSEMBLY INSTRUCTIONS SS2010 BASE SIZE 2 020m x 1 020m...

Page 2: ......

Page 3: ...r cladding used in Smart Store Sheds Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as above After a storm wash the cladding and the gutters as s...

Page 4: ...e Flashing 2 050m 1 Door 3 4 Sheet 1 810 m 2 Barge 1 110 m 2 TIMBER Padbolt Support 0 140 m 1 Bottom Plates H4 Green Front Back 2 020 m 2 Spouting 2 050 m 1 Bottom Plates H4 Green Sides 1 020 m 2 HARD...

Page 5: ...late Side Back Wall Sheets Front Wall Sheets Door Jambs Front Wall Sheet Door Sheets Door Side Flashing Padbolt Support Hinge Door Brace Door Top Bottom Channel QUICK OVERVIEW 1 LAY FOUNDATION 2 ASSEM...

Page 6: ...coming through from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bot...

Page 7: ...Rivet sheets together STEP 2 Position door side flash ings and assemble door as shown Drill and rivet as per dia gram ensuring rivets penetrate into door sheet STEP 4 Rivet door brace flashings onto b...

Page 8: ...then nail along the wall sheet to the Top Plate two clouts per pan see fig 1 STEP 4 Nail the wall sheets to the Bottom Plate at each end ensuring each side of wall sheets overhangs the end of Bottom...

Page 9: ...e wall sheets overhang the Top Plate by 15mm as shown Check that the Top Plate is straight then nail wall sheets to the Top Plate using two clouts per pan STEP 4 Nail the wall sheets to the Bottom Pla...

Page 10: ...the Door Jamb Flashing Ensure the door closes properly then fit remaining rivets STEP 3 Place 2 x Wall Sheets on timber Ensure that the top of the sheets are flush with the top of the Top Plate and t...

Page 11: ...panels while they are screwed together Before fixing ensure that the Side Panel overlaps the Back Panel Using 4 x 75mm screws screw the Top Plates together Using 4 x 40mm screws screw the Bot tom Pla...

Page 12: ...ts on both sides The Clear Roof Panel must be secured to the front and back Top Plates Pre drill and fasten with the 40mm weatherseal nails provided SELECT 4 x 1 110 Roof Sheets 1 x 2 050 Spouting 2 x...

Page 13: ...x to the Bottom Plate and the concrete slab A 10mm masonry drill bit is required OPTIONAL SENTRY FLOOR Position the Floor Joists centrally between the side Base Plates and skew nail each end with two...

Page 14: ......

Page 15: ...s less than 200g m2 as published by Branz Warranty certificate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Fast...