background image

7

CHECK

TRACE

CONTROL

4.1 Mounting

The SmartPoint has a single mounting hole in the center of the casing. This can be used in various ways to attach the device to the 

required surface (e.g. bolt, cord, or tie wrap).

Warning

: Avoid the use of metallic or magnetical materials for the mounting material.

Info

: The placement of the SmartPoint and/or the materials surrounding it, can have a (negative) impact on the radio range. Pre

-

vent the use of any metallic materials around the device. Install the device with an air gap of >4 cm from walls.

SL-SP-T/ERS mounting

Status: door closed

Status: door opened

MEDER

M

agen

t    

      M

04 
       
   H6 / 8

Model: SL-SP-T/ERS

Article No: 905-SMPT-024-016    

00:0e

MEDER

M

agen

t    

      M04 

       
   H6 / 8

Model: SL-SP-T/ERS

Article No: 905-SMPT-024-016    

00:0e

Install the SmartPoint  T/ERS with external reed sensor as depicted above.

Warning

: Ensure that the external sensor cable cannot be pulled out of the device. Any force applied to the cable may cause da

-

mage, even if the damage is not visible from outside. The cable has limited pull relieve.

SL-SP-T/H and SL-SP-T/HO mounting

• 

 Ensure that proper airflow is possible around the relative air humidity sensor.

• 

 Do not block the opening of the sensor.

• 

 Keep the sensor clean. Dust and condensation on the sensor membrane can cause an unwanted effect on the sensor.

• 

 Do not spray water directly on the sensor opening. This may damage the membrane protecting the sensor and electronics.

Magnet

Magnet

Reed-

sensor

Reed-

sensor

Smart-

Point

T/ERS

Smart-

Point

T/ERS

Status: door closed

Status: door opened

User Manual

SmartPoint/SmartPoint One

Summary of Contents for SmartPoint One T/W

Page 1: ...se the Smart Point model PRODUCT RANGE SmartPoint T Wireless temperature datalogger SmartPoint T H Wireless temperature and humidity datalogger SmartPoint T W Wireless temperature datalogger with exte...

Page 2: ...ational check in hibernation mode 5 3 3 Activation 6 4 SmartPoint operation 6 4 1 Mounting 7 4 2 Extended sleep 8 4 3 Logging 9 4 4 Operational check in active mode 9 4 5 Operational check before use...

Page 3: ...to 65 C 1 0 C max from 65 C to 85 C Relative air humidity in typical accuracy 2 0 RH up to 3 years SL SP T 1W Facility monitoring Shipment monitoring 1 0 C max from 40 C to 0 C 0 5 C max from 0 C to 6...

Page 4: ...ar SL SP T HO Facility monitoring Shipment monitoring 1 0 C max from 40 C to 0 C 0 5 C max from 0 C to 65 C 1 0 C max from 65 C to 85 C Relative air humidity in typical accuracy 2 0 RH up to 1 year SL...

Page 5: ...ode and do not show any activity on the device itself nor in SmartView If you plan to not actively use the SmartPoint in the next month of delivery it is advised to keep the device in hibernation mode...

Page 6: ...ibernation again Only valid during the activation process If the procedure has been carried out correctly the LED blinks shortly every 45 seconds Information Sometimes the activation of the SmartPoint...

Page 7: ...nt M04 H6 8 Model SL SP T ERS Article No 905 SMPT 024 016 00 0e Install the SmartPoint T ERS with external reed sensor as depicted above Warning Ensure that the external sensor cable cannot be pulled...

Page 8: ...rtLine network it enters extended sleep mode In this mode the SmartPoint continues to measure as regular however it does not attempt to transmit Information SmartPoints are not transmitting when outsi...

Page 9: ...ry pack Never use a SmartPoint with damaged label Never use SmartPoints with punktured membrane of humidity sensors Although SmartPoints report alarms to SmartView when their battery is low it is good...

Page 10: ...tPoint out of the reach of children The battery complies with IATA DGR Packaging Instruction 970 Section 2 and is therefore not considered as dangerous good Consult IATA regulation before use in airfr...

Page 11: ...rie Canada pour un environnement non contr l EU INFORMATION EUROPEAN UNION Product SmartPoint Models SL SP T SL SP TO SL SP T H SL SP T HO SL SP T ERS SL SP T 1W SL SP T 1WO This equipment is in confo...

Reviews: