background image

5

User Manual

CHECK

TRACE

CONTROL

SmartPoint/SmartPoint One

2. SmartPoint description

Model

LED

Flashlight

Product 

Type

Article

 

No.

SmartPoint front view

Company

Information

IP Class

FCC and IC

Information

optional 

Humidity

Sensor

SmartPoint back view

3. SmartPoint activation

SmartPoints are delivered in “hibernation” mode and they need to be activated before they can be used. See 3.3 how to activate 

the SmartPoint.

3.1 Stock keeping

In hibernation mode, SmartPoints are not actively measuring and reporting sensor readings. This mode ensures that the energy 

stored in the device battery is only little used during stock keeping of the device. Upon delivery, the devices are in hibernation 

mode and do not show any activity on the device itself nor in SmartView.
If you plan to not actively use the SmartPoint in the next month of delivery, it is advised to keep the device in hibernation mode. 

Once the SmartPoint is activated, it cannot be put back to hibernation mode again. 

3.2 Operational check in hibernation mode

The operational functioning of the SmartPoint can be checked in hibernation mode.

 

During the check, the LED of the device will blink and the SmartPoint transmits a few messages to SmartView, if an active

 

SmartLine network is detected.

• 

 Place the SmartPoint on the indicated position on the SmartMat.

•  Hold it steady in place. 

• 

After

 

5 seconds

, the LED shows activity and the SmartPoint contacts the SmartLine 

network.

• 

Keep the SmartPoint steady in place for an additional 

15 – 25 seconds.

The LED flashes long for 

5 times

, remove the SmartPoint 

immediately

 from the Smart-

Mat.

Summary of Contents for SmartPoint One T/W

Page 1: ...se the Smart Point model PRODUCT RANGE SmartPoint T Wireless temperature datalogger SmartPoint T H Wireless temperature and humidity datalogger SmartPoint T W Wireless temperature datalogger with exte...

Page 2: ...ational check in hibernation mode 5 3 3 Activation 6 4 SmartPoint operation 6 4 1 Mounting 7 4 2 Extended sleep 8 4 3 Logging 9 4 4 Operational check in active mode 9 4 5 Operational check before use...

Page 3: ...to 65 C 1 0 C max from 65 C to 85 C Relative air humidity in typical accuracy 2 0 RH up to 3 years SL SP T 1W Facility monitoring Shipment monitoring 1 0 C max from 40 C to 0 C 0 5 C max from 0 C to 6...

Page 4: ...ar SL SP T HO Facility monitoring Shipment monitoring 1 0 C max from 40 C to 0 C 0 5 C max from 0 C to 65 C 1 0 C max from 65 C to 85 C Relative air humidity in typical accuracy 2 0 RH up to 1 year SL...

Page 5: ...ode and do not show any activity on the device itself nor in SmartView If you plan to not actively use the SmartPoint in the next month of delivery it is advised to keep the device in hibernation mode...

Page 6: ...ibernation again Only valid during the activation process If the procedure has been carried out correctly the LED blinks shortly every 45 seconds Information Sometimes the activation of the SmartPoint...

Page 7: ...nt M04 H6 8 Model SL SP T ERS Article No 905 SMPT 024 016 00 0e Install the SmartPoint T ERS with external reed sensor as depicted above Warning Ensure that the external sensor cable cannot be pulled...

Page 8: ...rtLine network it enters extended sleep mode In this mode the SmartPoint continues to measure as regular however it does not attempt to transmit Information SmartPoints are not transmitting when outsi...

Page 9: ...ry pack Never use a SmartPoint with damaged label Never use SmartPoints with punktured membrane of humidity sensors Although SmartPoints report alarms to SmartView when their battery is low it is good...

Page 10: ...tPoint out of the reach of children The battery complies with IATA DGR Packaging Instruction 970 Section 2 and is therefore not considered as dangerous good Consult IATA regulation before use in airfr...

Page 11: ...rie Canada pour un environnement non contr l EU INFORMATION EUROPEAN UNION Product SmartPoint Models SL SP T SL SP TO SL SP T H SL SP T HO SL SP T ERS SL SP T 1W SL SP T 1WO This equipment is in confo...

Reviews: