3.3 Activation
The SmartPoint can be woken from hibernation mode by using a SmartMat.
Only activate SmartPoints when a SmartLine network is active and the SmartPoints are within 5 meter range of a SmartGate or
SmartRouter. Before activation, check if the SmartGate or SmartRouter indicate active network (see SmartGate or SmartRouter
manual).
Information
: The SmartPoint has an internal clock which is used to timestamp sensor readings. Upon activation, the internal clock
of the device must be set by a SmartLine network.
•
Place the SmartPoint on the indicated position on the SmartMat.
•
Hold it steady for about
5 seconds
until the LED blinks.
• Remove it immediately from the mat.
• If it is placed on the SmartMat for longer than
15 – 25 seconds
, the SmartPoint goes
to the hibernation again. (Only valid during the activation process.)
•
If the procedure has been carried out correctly, the LED blinks shortly every
45 seconds
.
Information
: Sometimes the activation of the SmartPoint is not successful e.g. due to movement of the SmartPoint. Retry the
activation procedure after 15 minutes.
Keep the SmartPoint close to the SmartGate or SmartRouter for 30 minutes. During the 30 minutes, other SmartPoints may be
activated.
After 30 minutes, verify the operation of the device in SmartView. Find the serial ID of the SmartPoint in the list of your devices in
SmartView and verify that one or more readings of the SmartPoint have appeared.
4. SmartPoint operation
After activation, the SmartPoint measures and reports sensor values based on a factory configured interval. Measurement points
are also stored in the SmartPoint when no radio connection can be established. This makes the SmartPoint suitable to monitor
goods during shipment.