US SL-608 OUTDOOR High Lifter 01/2017
24
2. Stop-Down at ”movements” controlled via control panel
If – no response to pushing control panel, all functions
Has emergency stop been released? Reconnect emergency stop by turning the emergency button. Check
whether main switch is on (placed on battery case between lift actuators) – to be turned clockwise to
switch on.
Check whether the control panel connector is correctly placed in the control box. Have batteries been
charged? – on/off button on handle for drive should be on to read battery indicator?
Is 30-ampere fuse in control box OK?
Has the safety switch been activated? If activated, try to deactivate by pulling in the telescopic arm, or act
as follows:
The safety switch has shut off the machine.
To re-establish function on the machine, you
may, for instance, using a screwdriver push
up the switch, and the safety switch will
resume its function
The telescopic arm is run back in, and work
too heavy for the machine is lowered back in
place. Should the safety switch switch off
again at this manoeuvre, you may, using your
body weight, push the machine in place by
applying pressure on the weight blocks.
© 2006 Copyright. www.smartlift.dk