31
FXO routing table
Calls from FXO interface are routed according to “FXO calls rote to” parameter. You
can set SmartGate as DialThru gateway or as gateway for extension line of PBX.
You can program ME function for the DialThru gateway.
For gateway for extension line of PBX you can fill in the FXO routing table.
According to the prefix of dialed number on FXO interface you can:
·
Bar the number to be dialed – SmartGate hangs up, the call isn’t established;
·
Accelerate connection establishing by knowing the number length for the given
prefix;
·
Accelerate connection establishing by allowing to terminate dialing with a #;
·
Modify the number to be dialed by removing and/or adding prefix.
The principle of table function is the same as in the FXS routing table. The call is
controlled according to parameters on the row with dialed number prefix match.
Remember to fill in the "Other prefixes" line for a number whose prefix is not found in
the table.
FXO calls route to
The main parameter for FXO calls routing. You can program SmartGate as
DialThru gateway, or as gateway for extension line of PBX.
DialThru gateway:
Incoming ringing is immediately connected to FXS interface. If function ME set,
SmartGate starts to establish GSM call to ME number after defined number of
rings. Routing table FXO is disabled.
gateway for extension line of PBX:
SmartGate detects incoming ringing and Off-Hook the line after programmed
number of rings, if it is possible to make call to GSM. SmartGate generate dial
tone and after dialing takes an action according to FXO routing table.
Setting options:
FXS
- DialThru gateway
GSM
- gateway for extension line of PBX
Default setting: FXS - DialThru gateway
ME number
If you program SmartGate as DialThru gateway, fill in telephone number for ME
function. SmartGate starts to establish GSM call to ME number after defined
number of rings. Then you can receive incoming FXO call on telephone line or in
GSM
network.
Blank
parameter
disables
ME
function.
Setting options: 0-16 characters (0-9,*,#,+)
Default setting: blank
Number of rings to ME
If you program SmartGate as DialThru gateway and ME number is filled in,
SmartGate starts to establish GSM call to ME number after defined number of
rings. Then you can receive incoming FXO call on telephone line or in GSM
network.
Setting options: 0-255
Step:
1
Default setting: 1
Summary of Contents for 2N