22
9.2. Parameter Tables
All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, description of SmartGate's behavior, setting options,
setting step and default value (value after initialization). Identical texts are displayed as
help hints in PCManager program.
9.2.1. Telephone interface FXS parameters
Type of dialing
Select the dialing type to be received by SmartGate on the FXS interface.
SmartGate accepts only the selected type of dialing, ignoring the others.
Setting options:
DTMF
-SmartGate receives tone dialing only.
Pulse
-SmartGate receives pulse dialing only
Default setting: DTMF
Timeout for dialing end recognize
[s]
Timeout during which SmartGate waits for further digits to be dialed. It starts to
establish connection when this timeout passes.
Setting options: 1-255 s
Setting step:
1 s
Default setting: 5 s
Minimal On Hook
[ms]
The minimum line current break that SmartGate evaluates as hang-up.
Setting options: 100-25500 ms
Setting step:
100 ms
Default setting: 500 ms
Beep after dialing end
Select a beep to signal the end of dialing (beginning of outgoing call
establishing).
Setting options: YES/NO
Default setting: YES
Dial tone – frequency
[Hz]
Setting of frequency/frequencies of dial tone.
Setting options: 1-3400 Hz
Setting step:
1 Hz
Default setting: 425 Hz
Summary of Contents for 2N