background image

Longo programmable controller LPC-2.DP1

STANDARDS   AND   PROVISIONS:   Standards,   recommendations,
regulations  and provisions  of  the  country  in  which  the  devices  will
operate, must be considered while planning and setting up electrical
devices. Work on  100 .. 240 V AC  network is allowed for authorized
personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.

WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, warranty of 24 months is valid from the date of
sale to the end buyer, but not more than 36 months after delivery
from Smarteh. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous  voltage  in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).

If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately!

LONGO LPC-2 complies to the following standards:

EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-
3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013

LVD: IEC 61010-1:2010 (3

rd

 Ed.), IEC 61010-2-201:2013 (1

st

 Ed.)

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Summary of Contents for LPC-2.DP1

Page 1: ...USER MANUAL Longo programmable controller LPC 2 DP1 Temperature Control panel Version 4 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 DP1 Written by SMARTEH d o o Copyright 2016 SMARTEH d o o User Manual Document Version 4 March 2016 i...

Page 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Page 4: ...1 2 FEATURES 2 3 OPERATION 3 3 1 Operational modes 3 3 2 Functions 4 3 3 Parameters 5 4 INSTALLATION 7 4 1 Connection scheme 7 4 2 Mounting frame selection 9 4 3 Mounting instructions 10 4 4 Module l...

Page 5: ...eed I speed II speed III AUTO or OFF modes of operation can be selected Fan mode is represented with left blue LCD bar graph With ECO economy OFF and ERR error signs on LCD CP status is represented Co...

Page 6: ...controller off 10 position LCD bar graph for temperature set point 4 position LCD bar graph for manual fan speed auto and controller off Light intensity measurement LCD intensity control Step less or...

Page 7: ...led Display will return to stand by mode if touch buttons are not pressed for a while 5 seconds Changing operation modes Request for switching between CP normal and economic operating mode is done wit...

Page 8: ...re and temperature set point is 1 C the PI output value will increase every second by 1 On the other hand if the difference is 1 C the PI output value will decrease every second by 1 2 4 pipe system s...

Page 9: ...sed Winter Summer Used only for two pipe system to change calculation for Hot valve and Fan speed Winter heating 0 to Summer cooling 1 4 2 pipe Four pipe system manages hot and cold water pipes simult...

Page 10: ...into PI calculation algorithm as SP Fan mode set Fan mode on CP panel can be remotely changed by main module 0 1 2 3 4 Off I II III auto The change is made by setting the Fan Remote Cmd command bit Re...

Page 11: ...Longo programmable controller LPC 2 DP1 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme 7...

Page 12: ...cted II middle speed selected III maximum speed selected AUTO auto speed selection OFF module functions switched off TB1 Up left Fan mode Increase Mode speed selection TB2 Down left Fan mode Decrease...

Page 13: ...were not verified by Smarteh Before installation verify compatibility of non listed frames Module housing has a fin on each side which can be easily removed with knife cutter or pliers This adaptation...

Page 14: ...connected to the main power supply Module should be positioned in the wall inside of the room Avoid direct sunlight or positioning near heating cooling source object Usage of cover frames and holders...

Page 15: ...DP1 with cover plate LPC 2 DP1 is connected to the main module with interconnection cable e g SSK ICM 7 which must be ordered together with LPC 2 DP1 module When more modules e g LPC 2 CR1 LPC 2 CH1...

Page 16: ...ounting module 01 derivation code 001 version code reserved for future HW and or SW firmware upgrades D C 01 10 is the date code 01 week and 10 year of production Label 2 description S N DP1 S9 090000...

Page 17: ...Longo programmable controller LPC 2 DP1 5 REGULATION DIAGRAM 13...

Page 18: ...main module Interconnection connector type RJ 12 6 6 Power consumption 1 W Dimensions W x H x D 75 x 49 x 29 mm Weight 50 g Maximum altitude 2000 m Mounting position horizontal Ambient temperature 0 t...

Page 19: ...scribes all the changes to the document Date V Description 30 03 16 4 Added sentence about sealing junction box and pipes on page 10 01 07 12 3 CGP General update 20 07 10 2 Updated regulation diagram...

Page 20: ...Longo programmable controller LPC 2 DP1 8 NOTES 16...