44
SMARTEK Vision | User Manual – LED Strobe Controller Family | Doc. v2.1.1
7.8. Trigger Input
7.8.1.
Trigger Input Parameters
With the trigger parameters, the timing options of the Trigger- (OUT) and LED-outputs (LED)
are configured.
Figure 32: ScLibClient – Trigger Parameters
All parameters have a resolution of 1µs:
•
Trigger Edge
– configuration of controller's input trigger edge. If the trigger edge is not
the same between camera and strobe controller, asynchronization may occur between
them.
•
Delay Time
– time interval between the receipt of a trigger signal and the initiation of an
output pulse. The minimal delay time depends on device and current setup.
•
On Time
– definition of the pulse length. Please be careful with this parameter, too high
values of On Time can damage the light heads.
•
Off Time
– the time when no trigger is accepted, internal capacitors are recharged.
•
Trigger 1, 2, 3, 4 (flag)
– enable or disable trigger.