26
SMARTEK Vision | User Manual – LED Strobe Controller Family | Doc. v2.1.1
5. Status LEDs
The HPSC and IPSC series have a different concept of Status LEDs. The following chapter
describes the LEDs and signaling, as well as the error codes stated by those LEDs.
5.1. HPSC-Series
All Strobe Controllers of the HPSC-series provide a
green
and a
yellow
status LED on the front
panel of the device. Due to the different microcontroller architecture and differences in the boot-
up routine, the HPSC1 and HPSC4 are slightly different in signaling. They are coded as shown
in the following sections.
Note:
The USB and RS-232 versions provide separated status LEDs, on the Ethernet version
these LEDs are part of the Ethernet / RJ45 connector.
HPSC1
Status
Green
LED
Yellow LED
Description
Error
OFF
OFF
No sign of life
Flashing
Number of consecutive flashes as described in chapter 5.3 –
Error / Fault codes
Normal
Operation
ON
OFF
Running Mode: “OFF” active
ON
Running Mode: “Continuous” active
Flashing (fast)
(1Hz)
Running Mode: “External Trigger“ or “Software Trigger” active
Flashing (slow)
(0.5Hz)
Running Mode: “External Switch” or “Internal Trigger”
Booting
Flashing
---
Device in bootloader mode
Flashing
Receiving on data interface
Table 21: HPSC1 - Status LEDs and description
HPSC4
Status
Green
LED
Yellow LED
Description
Error
OFF
OFF
No sign of life
Flashing
Number of consecutive flashes as described in chapter 5.3
Error / Fault codes
Normal
Operation
ON
OFF
Running Mode: “OFF” active
ON
Running Mode: “Continuous” active
Flashing
(max. 17Hz)
Other Running Modes: Indicates trigger, flashing rate is
limited to max. 17 Hz
Table 22: HPSC4 - Status LEDs and description