LD303 - Operation and Maintenance Instruction Manual
4.18
204-0301 SENSOR FOR FLANGED PRESSURE TRANSMITTER (CONTINUATION)
CODE Flanges Bolts and Nuts Material
A0
A1
A2
Plated Carbon Steel (Default)
(16)
316 SST
Carbon Steel (ASTM A193 B7M)
(1) (16)
A5
Hastelloy C276
CODE Flange thread for fixing accessories (adapters, manifolds, mounting brackets, etc)
D0
D1
7/16” UNF (Default)
M10 X 1.5
D2
M12 X 1.75
CODE Flange Facing Finish
Q0
Q1
Q2
Q3
Q4
Raised Face – RF (Default)
Flat Face – FF
Ring Joint Face – RTJ (Only available for ANSI standard flange)
(12)
Tongue Face
(11)
Grooved Face
(11)
§
TYPICAL MODEL NUMBER
NOTES
( 1 )
Meets NACE MR – 01 – 75/ISO 15156 recommendations.
( 2 )
Silicone Oils not recommendations for Oxygen (O
2
) or
Chlorine service.
( 3 )
Not applicable for vacuum service.
( 4 )
Drain/Vent not applicable.
( 5 )
O’Ring should be Viton or Kalrez.
( 6 )
Maximum pressure 24 bar.
( 7 )
For remote Seal only 316 SST - CF8M (ASTM A3510 flange is
available (thread M12).
( 8 )
Fluorolube fill fluid is not available for Monel diaphragm.
( 9 )
Attention, check corrosion rate for the process, tantalum plate
0.1 mm, AISI 316L extension 3 to 6mm.
(10)
Item by inquiry.
(11)
Supplied without Gasket.
(12)
Gasket for housing, available only in Stainless 316.
(13)
Range of application of temperature from -40 ºC to 150 ºC.
(14)
Applicable only to:
-
Thickness of steel: 0.05 mm
- Diameter/capillary length:
2” ANSI B 16.5 DN 50 DIN, JIS 50 A, for seals up to 3 meters of
capillary and level models (by inquiry).
3” ANSI B 16.5 DN 80 DIN, JIS 80 A, for seals up to 5 meters of
capillary and level models.
- Faces: RF and FF;
- Temperature Range: +10 to 100 ºC
+ 101 to 150 ºC (by inquiry)
- Not applicable for diaphragm thickness;
- Not applicable for use with gaskets.
(15)
Inert Fluid: safe for oxygen service.
(16)
Not applicable for saline atmosphere.
(17)
Not available for slip-on flange.
(18)
Not available for integral flange.
204-0301
A0
D0
Q0
Summary of Contents for LD303
Page 1: ...Profibus PA Pressure Transmitter L D 3 0 3 M E...
Page 8: ...LD303 Operation and Maintenance Instruction Manual VIII...
Page 22: ...LD303 Operation and Maintenance Instruction Manual 1 14...
Page 26: ...LD303 Operation and Maintenance Instruction Manual 2 4...
Page 74: ...LD303 Operation and Maintenance Instruction Manual 4 6 Figure 4 4 Exploded View...
Page 83: ...Maintenance Procedures 4 15 Figure 4 8 TPE Software Screen...
Page 102: ...LD303 Certifications Information A 4 CSA NEMKO and EXAM CEPEL NEPSI...
Page 104: ...LD303 Certifications Information A 6 CEPEL...
Page 105: ...Appendix A A 7 Control Drawing Factory Mutual FM...
Page 106: ...LD303 Certifications Information A 8...
Page 108: ...LD303 Operation and Maintenance Instruction Manual B 2...