LD303 - Operation and Maintenance Instruction Manual
4.4
Figure 4.2 - Backup Ring Mounting
Electronic Circuit
Plug sensor connector and power supply connector to main board.
Attach the display to the main board. Observe the four possible mounting positions. (Figure 4.3 -
Four Possible Positions of the Display). The
SMAR
mark indicates up position.
Figure 4.3 - Four Possible Positions of the Display
Anchor the main board and display with their screws (
3
).
After tightening the protective cover (
1
), mounting procedure is complete. The transmitter is ready to
be energized and tested. It is recommended to open the transmitter's pressure taps to atmosphere
and adjust the TRIM.
Interchangeability
In order to obtain an accurate and better temperature compensated response. Each sensor is
submitted to a characterization process and the specific data is stored in an EEPROM located in the
sensor body.
Summary of Contents for LD303
Page 1: ...Profibus PA Pressure Transmitter L D 3 0 3 M E...
Page 8: ...LD303 Operation and Maintenance Instruction Manual VIII...
Page 22: ...LD303 Operation and Maintenance Instruction Manual 1 14...
Page 26: ...LD303 Operation and Maintenance Instruction Manual 2 4...
Page 74: ...LD303 Operation and Maintenance Instruction Manual 4 6 Figure 4 4 Exploded View...
Page 83: ...Maintenance Procedures 4 15 Figure 4 8 TPE Software Screen...
Page 102: ...LD303 Certifications Information A 4 CSA NEMKO and EXAM CEPEL NEPSI...
Page 104: ...LD303 Certifications Information A 6 CEPEL...
Page 105: ...Appendix A A 7 Control Drawing Factory Mutual FM...
Page 106: ...LD303 Certifications Information A 8...
Page 108: ...LD303 Operation and Maintenance Instruction Manual B 2...