23 9880023200-CU 36P NEUTRO 120312
In case of yellow flame on oven gas burner (
MOD: VEFSGGL65)
as well as of
distinct blue flame but lifting, call the technical assistance centre for further
control and fix to solve the problem
.
■
APPLIANCE PRESSURE REGULATOR CONVERSION
MOD: Oven Gas Range – Oven Dual Fuel Range
NOTE: All gas adjustment must be done by a qualified service
personnel only.
The unit appliance pressure regulator must be set to match the type gas
supply used. If converting from natural gas to LP gas, the appliance pressure
regulator must be converted to regulate LP gas. If converting from LP gas to
natural gas, the appliance pressure regulator must be converted to regulate
natural gas. In case of replacement gas regulator you must use a CSA
certified Pipe Sealant only
To convert the appliance pressure regulator from one gas to another; remove
the cap, push down and turn counter-clockwise. Turn the cap over and
reinstall, follow the NAT or LP indication (figure 17A and 17B).
NOTE:
THE GAS TYPE YOU ARE CONVERTING TO MUST BE VISIBLE
ON THE TOP OF THE INSTALLED APPLIANCE PRESSURE REGULATOR
CAP.
■
SERVICE – PARTS INFORMATION
MOD: Oven Gas Range – Oven Dual Fuel Range
When your range requires service or replacement parts, contact your dealer
or authorised service agency. Please give the complete model and serial
number of the range which is located on the range model number plate.
GAS VALVE BY-PASS CONVERSION
NOTE:
All gas adjustment must be done by a qualified service person
only.
To convert the rangetop:
Remove all the knobs, remove the control panel.
Using a small flat tip screwdriver switch the by-pass screws (figure 18A) with
a new one if necessary, according to the technical data chart (page 24). The
new by-pass screw must be totally closed.
To convert the gas oven:
Remove all the knobs, remove the control panel.
Using a small flat tip screwdriver, find the by-pass screws (figure 18B). Turn
right until the screw is completely closed. Then turn left the by-pass screw for