The machine is supplied factory lubricated and ready to run. It should be positioned on any solid,
level and non-skid work surface that is nonflammable. Install in work area with adequate light
and space.
-
You may place the mixer on bench which is capable of supporting a load of 25kg. For operation
stability, please punch four holes on the table and fix SM-500A onto the table by four screws.
Please see
Figure 1
.
-
DO NOT attempt to lift the mixer alone. This
machine is 15 kg. The transportation should
require two people, please see
Figure 2
-
Clean the mixer before use. It is normal for the
factory to apply a generous amount of grease
in and on the machine before initial use.
-
During the transportation or fitting, please do
not lean over 35 degree to avoid the gear oil
leaking from the gear oil container.
ELECTRICAL CONNECTION
CAUTION:
NEVER USE EXTENSION CORD. Low amp supply could damage the mixer or cause a fire
.
Before connecting this machine to the electrical supply, check that the details on the rating plate (located
on the rear of the machine) correspond to the details of your electrical connection.
The mixer is supplied with a trailing lead fitted with a molded plug. If the style of plug is unsuitable for the
socket you plan to use, the plug must be cut off and replaced with an appropriate plug.
Machines are fitted with a color coded three core cable as follows:
(1)
Brown: Live
(2)
Blue: Neutral
(3)
Green/Yellow: Earth
As the color of the wires may not correspond to the colored markings identifying the terminals in your
plug, you should proceed as follows:
-
The wire which is colored blue must be connected to the terminal which is marked with the
letter N or colored black.
-
The wire which is colored brown must be connected to the terminal which is marked with the
letter L or colored red.
-
The wire which is colored green/yellow must be connected to the terminal which is marked with
the letter E or colored green.
The mixer should be plugged into a switched socket which isolates all poles and has a minimum contact
clearance of 3mm and located close to the mixer for use in an emergency and to facilitate servicing.
The machine must be incorporated into a potential equalization system.
The leakage current for this appliance is no greater than 1 mA/KW.
If the electrical supply cable to the machine becomes damaged, it must be replaced by a specification or
higher and suitable for the Mixer’s motor load.
The ground wire is fixed to the machine and this connection must be kept intact.
CAUTION:
The mixer MUST be grounded.
Installation Instructions