SMA Solar Technology AG
Parameter lists
Technical Description
SI5048-TEN093630
171
19.2.6 Password Setting (280#)
You can find detailed information about this menu in chapter 10.5 ”Entering the installer password”
(page 73).
15
SlpStpTm
Stop time for switching off
at night (sleep mode)
05:00:00
hh:mm:ss
23
Box
Type of Multicluster Box
used
MC-Box-6
Multicluster
Box 6.3
MC-Box-9
Multicluster
Box 9.3
MC-Box-12 Multicluster
Box 12.3
24
ClstMod
Cluster type in multicluster
operation
Single
Cluster
MainCluster
ExtensionClst
1
ExtensionClst
2
ExtensionClst
3
25
ClstAdr
Cluster address
28
ChrgCtlOp
Typ of DC charging
device
Auto
Automatic
Auto
DCOnly
Battery charger
only
SMA
Sunny Island
Charger
30
RnMod
"Run mode"
Reaction in case of
failures
RunAlways
always
available
RunAlways
StopAlways Stop in case of
device failure
31
CurCtl
Location of the current
control
External
External
Internal
Number Name
Description
Value
Description
Default
value
Summary of Contents for SI 5048
Page 2: ......
Page 10: ...Table of Contents SMA Solar Technology AG 10 SI5048 TEN093630 Technical Description...
Page 43: ...SMA Solar Technology AG Electrical Connection Technical Description SI5048 TEN093630 43...
Page 209: ......
Page 210: ......
Page 212: ...4 4PMBS 5FDIOPMPHZ XXX 4 EF...