2 Safety
SMA Solar Technology AG
Operating manual
EDML-10-BE-en-13
11
IP addresses in local networks
In local networks in which no DHCP server is active, suitable IP addresses from the free
address pool of the network segment must be assigned to all nodes to be integrated during
initial commissioning.
If the IP addresses in the local network are to be assigned dynamically, DHCP must be
activated in the router (see the router manual). The DCHP server automatically assigns the
appropriate network settings to your nodes in the local network. A manual network
configuration is therefore not necessary.
Completion of data after interruption of communication
If the data communication between the Data Manager and SMA products connected via
SMA Speedwire is interrupted, the data will be retrieved subsequently for the time of the
interruption. Data is retrieved with a maximum interruption period of 7 days. Existing data of
newly connected SMA products will not be transmitted until the Data Manager is
commissioned. Historical data of SMA products are only available in the user interface of the
SMA product.
Possible causes for the interruption of the data communication can be:
• Interruptions of the SMA Speedwire connection
• Resetting connected SMA products over a period of several hours
• Voltage supply interruption
2.3
Supported Products
Supported SMA Products
Availability of SMA products in your country
Not all SMA products are available in all countries. For information on whether an SMA
product is available in your country, contact your distributor.
Inverters:
• All SMA inverters with integrated or retrofitted Speedwire/Webconnect interfaces are
supported. Information on whether an SMA inverter has an integrated Speedwire/
Webconnect interface or can be retrofitted with a Speedwire/Webconnect interface can be
found on the SMA inverter product page at www.SMA-Solar.com.
All SMA central inverters with integrated Modbus interfaces are supported.
Additional products:
• SMA Com Gateway from firmware version 01.00.40.R
• SMA Energy Meter from firmware version 1.1 (not available in all countries)
• Sunny Portal powered by ennexOS
• 1 SMA Inverter Manager with 1 Sunny Tripower Storage 60
• 1 SMA Inverter Manager with up to 42 Sunny Tripower 60 / Sunny Highpower Peak1
• SMA Hybrid Controller
• SMA Data Manager M