11
The remote
control does not
work.
The distance between the machine
and the remote control is too far.
Let the remote control get close to the air
conditioning, and make sure that the remote
control directly faces to the direction of the
remote-control receiver.
The remote control is not aligned
with the direction of the remote
control receiver.
Batteries are dead.
Replace batteries.
Displays 'E1'.
The pipe temperature sensor is
abnormal.
Clean filters and restart. Refer to service
centre if issue still persist.
Displays 'E2'
The room temperature sensor is
abnormal.
Clean filters and restart. Refer to service
centre if issue still persist.
If problems not listed in the table occur or recommended solutions do not work, please contact the
service centre.
APPENDIX
Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste
must be handled separately as special treatment is necessary. Recycling facilities are now
available for all customers at which you can deposit your old electrical products. Customers
will be able to take any old electrical equipment to participating civic amenity sites run by
their local councils. Please remember that this equipment will be further handled during the recycling
process, so please be considerate when depositing your equipment. Please contact the local council
for details of your local household waste recycling centres.
TECHNICAL DATA
MODEL
CLIM9000CE
Capacity Cooling
2.06kWh, 8000BTU
Rated Input
890 W
Running Current
3.95 A
Air Flow
330m³/h
EER rate
A
Compressor
Rotary, R410A gas
Noise
38-54dB(A) Sound Energy <65dB(A)
Sound Power
Thermostat
16-31
℃
Moisture removal
22L/Day
Permitted Excessive Operating
Pressure
0.8/3.2MPa
Maximum Allowable Pressure
1/5Mpa
Power Supply
220-240V/50Hz
Net Weight
21kg
Dimension(L*D*H)
345*378*870mm
Unit must be vented outside when in Air Cooling and Heating mode. For
the purposes of EU regulation EN12102 this is a local air conditioner and
produces less than 65dB(A) sound energy.