background image

 

SAFETY INSTRUCTIONS 

Important! 
• Carefully read the instructions before operating the unit 
• This appliance is for indoor use only. 
• Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. 
• Installation must be in accordance with regulations of the country where the unit is used. 
• If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, 
modified by a qualified electrician. 
• This air conditioner has been tested and is safe to use. However, as with any electrical appliances - use it with 
care. 
• Disconnect the power plug from socket before dismantling, assembling or cleaning. 
• Avoid touching any moving parts of the appliance. 
• Never insert fingers, pencils or any other objects though the guard 
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless 
they have been given supervision or instruction concerning the use of the appliance by a person responsible for 
their safety. 
Do not leave children unsupervised with this appliance. 
• Do not clean the unit by spraying it or immersing it in water. 
• Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should 
be installed by a qualified electrician. 
• Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or 
exposed to sharp object/edges. 
• A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a 
hazard. 
• Any service other than regular cleaning or filter replacement should be performed by an authorised service 
representative. Failure to comply could result in a voided warranty. 
• Do not use the appliance for any other purposes than its intended use. 
• The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may 
be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit. 
• Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. 
This prevents damage to the compressor. 
• Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF 
switch located on the control panel. 
• Always place the unit on a dry and stable surface. 
• The appliance should not be installed in laundry or wet rooms 
 
Energy Saving and Unit Safety Protection Tips 
• Do not cover or restrict the airflow from the outlet or inlet grills. 
• For maximum performance the minimum distance from a wall or objects should be 50cm. 
• Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks 
(approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, 
depending on the air quality. 
• For the initial start up set the fan speed to maximum and the thermostat to 4-5 degrees lower than the 
current temperature. After, set the fan switch to low and set the thermostat to your desired setting. 
• To protect the unit we recommend not using the cooling function when the ambient temperature is higher 
than 35

o

C. 

 

Summary of Contents for CLIM9000CE

Page 1: ...CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference...

Page 2: ...supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard Any service other than regular cleaning or filter replacement should be performed by an author...

Page 3: ...g Cap 12 Power supply cord Installation Warning Before using this unit please keep it upright for at least 3 4 hours This unit can easily be moved from one room to another While moving the unit please...

Page 4: ...s and outlet grills 6 Fix the other end of the hose to the air outlet window kit Note The window kit is only designed to be installed with sliding or sash windows or doors The window kit is not design...

Page 5: ...is length the unit may malfunction and this can invalidate the warranty The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat Avoid bending the air hose mo...

Page 6: ...s Castors and handles for portability Compressor protection technology for extended life span 2 OPERATION Selection Keys and Display Indicator LED 1 Power On Off 9 Tank Full indicator light 2 Mode Sel...

Page 7: ...ss TIMER to adjust the timer from 1 to 24 hours Timer indicator turns on Unit will start after selected number of hours Under power on mode press TIMER to setup power off timer Press TIMER to adjust t...

Page 8: ...an alarm and the LCD temperature display area will show FL At this point you need to move the drainage pipe connecting the machine or the water outlet to sewer other drainage area or a flat tray to e...

Page 9: ...vaporated Please do not use continuous drainage if you intend to use the self evaporating facility Maintenance Cleaning Please shut off the unit and unplug from the mains before cleaning or performing...

Page 10: ...e it as directed in this user manual and only perform operations advised here Problems Reasons Solutions The air conditioning does not work There is no electricity Turn it on after connecting it to a...

Page 11: ...eatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to parti...

Page 12: ...rm 1 Has the unit been standing upright for at least 2 hours 2 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restar...