background image

10 

 

b: Put the evaporator filter screen into warm water with neutral detergent (about 40

 /104

) and dry it in 

the shade after rinsing clean.       

B: Clean the lower filter screen frame 

a: Hold the handle of the air inlet filter screen frame, and pull it outward gently to remove it. 
b: Put the    filter screen into warm water with neutral detergent (about 40

 / 104 

) and dry it in the shade 

after rinsing clean. 

                                                     

End of Season Maintenance 

1.

 

Pull out the plug from the drainage hole and empty the internal tank. You can also drain the water by 
leaning the unit.   

2.

 

Then switch the unit to low fan mode.     

3.

 

Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the inside of the 
unit dry and prevents mold developing   

4.

 

Turn off the unit and pull out the plug.     

5.

 

Coil the wire and bind it together, then put it into the accessories space.   

6.

 

Separate the air-exhaust pipe and store it safely.     

7.

 

Cover the unit and keep it in a dry place.   

8.

 

Take the batteries out of remote control and store or dispose, them safely   

Keep all accessories with the unit ready for next season.   

 

 

Troubleshooting 

Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and 
may lead to failure, causing injuries and property damage. Only use it as directed in this user manual 
and only perform operations advised here.

 

Problems 

Reasons 

Solutions 

The air 
conditioning 
does not work. 

There is no electricity.   

Turn it on after connecting it to a socket with 
electricity.   

The overflow indicator displays "FL".

 

 

Discharge the water inside. 

The ambient temperature is too low 
or too high 

Only use to use the machine within 
temperature range of 7-35

℃ 

(44-95

).   

In cooling mode, the room 
temperature is lower than the set 
temperature; in heating mode, the 
room temperature is higher than the 
set temperature. 

Change the set temperature.   

In dehumidification mode, the 
ambient temperature is low.

 

The machine is placed in a room with an 
ambient temperature of greater than 17 

.

 

(62 

).

 

 
The cooling or 
heating effect is 
not good   

There is direct sunlight.   

Use curtains to reduce the direct sun heat 

Doors or windows are open; there are 
a lot of people; or in cooling mode, 
there are other sources of heat (e.g. 
fridges)   

Close doors and windows; increase air 
conditioning power 

The filter screen is dirty.   

Clean or replace the filter screen.   

The air inlet or outlet is blocked.   

Clear obstructions; make sure venting is 
correct as described in this user manual and 
hose is not bent   

Loud Noise 

The air conditioning is not placed on a 
flat surface.   

Put the air conditioning on a flat and hard 
place (to reduce noise). 

Compressor 
does not work.   

Overheat protection starts.   

Wait for 3 minutes until the temperature is 
lowered, and then restart the machine. 

Summary of Contents for CLIM9000CE

Page 1: ...CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference...

Page 2: ...supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard Any service other than regular cleaning or filter replacement should be performed by an author...

Page 3: ...g Cap 12 Power supply cord Installation Warning Before using this unit please keep it upright for at least 3 4 hours This unit can easily be moved from one room to another While moving the unit please...

Page 4: ...s and outlet grills 6 Fix the other end of the hose to the air outlet window kit Note The window kit is only designed to be installed with sliding or sash windows or doors The window kit is not design...

Page 5: ...is length the unit may malfunction and this can invalidate the warranty The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat Avoid bending the air hose mo...

Page 6: ...s Castors and handles for portability Compressor protection technology for extended life span 2 OPERATION Selection Keys and Display Indicator LED 1 Power On Off 9 Tank Full indicator light 2 Mode Sel...

Page 7: ...ss TIMER to adjust the timer from 1 to 24 hours Timer indicator turns on Unit will start after selected number of hours Under power on mode press TIMER to setup power off timer Press TIMER to adjust t...

Page 8: ...an alarm and the LCD temperature display area will show FL At this point you need to move the drainage pipe connecting the machine or the water outlet to sewer other drainage area or a flat tray to e...

Page 9: ...vaporated Please do not use continuous drainage if you intend to use the self evaporating facility Maintenance Cleaning Please shut off the unit and unplug from the mains before cleaning or performing...

Page 10: ...e it as directed in this user manual and only perform operations advised here Problems Reasons Solutions The air conditioning does not work There is no electricity Turn it on after connecting it to a...

Page 11: ...eatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to parti...

Page 12: ...rm 1 Has the unit been standing upright for at least 2 hours 2 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restar...

Reviews: