24 / 42
Screen 22: Alarm Settings
Option
Value
Explanation
ALARM ACT
NONE
No action is performed on alarm.
AUTO SCAN
The camera performs an auto scan on alarm: the camera
performs a 360 horizontal scan operation.
RANDOM SCAN
The camera performs a random scan on alarm: the camera
performs a random 360° scan, pausing for approximately 2”
every 142°.
FRAME SCAN
The camera performs a frame scan on alarm: the horizontal scan
is performed in the SET SCAN limits.
PRESET
The camera goes to related preset on alarm.
PATTERN 1
The camera performs pattern action 1 on alarm.
PATTERN 2
The camera performs pattern action 2 on alarm.
PATTERN 3
The camera performs pattern action 3 on alarm.
PATTERN 4
The camera performs pattern action 4 on alarm.
CRUISE
The camera performs a cruise on alarm: the camera runs a cycle
consisting of up to 30 preset positions.
TRACKING
The camera performs tracking action on alarm.
PRESET N TRA
The camera goes to related preset and starts tracking function.
CRUISE TRA
The camera performs a cruise with tracking on alarm.
ACTIVATE AUX
OFF
Turn on/off the relay output after the alarm.
ALARM CONTACT
ON, OFF
This determines the current AUX gives output actions or not. It is
related to the above setting
ACTIVATE AUX
.
Table 18
If an alarm is triggered during any automatic operation of the camera (Pattern, Auto Tracking, etc.), the operation
in progress is stopped and the camera executes the action that has been set in the
ALARM ACT
menu:
In the event of Preset action, the camera moves to the preset position. Then, if the option
PARK ACTION
is
set to execute an action, the action will be executed after the
PARK TIME
period has expired.
In the event of "
PATTERN, AUTO SCAN, RANDOM SCAN, FRAME SCAN, CRUISE
" actions, the action is
executed by the camera permanently and can only be stopped by one of the following actions: any
command sent by a controller or any alarm event.
4.5.4.2. ADDR
SETTING
Screen 23: Address Setting
The soft address is the address programmed by built-in software. The hard address is the address programmed by the
DIP Switch.
Option
Value
Explanation
ALARM NUMBER 1
ALARM
ACT
NONE
ACTIVATE
AUX OFF
ALARM
CONTACT
OFF
BACK
EXIT
ADDR SETTING
ADDR
TYPE
HARD
ADDR
HARD
255
ADDR
SOFT
0
<EDIT ADDR SOFT>
BACK
EXIT