Set discharge current on the left and final voltage
on the right. The discharge current ranges from
0.1 to 5.0A. To start the process, press
Start/Enter
key for more than 3 seconds.
The screen displays the current state of
discharge. You can alter the discharge current by
pressing
Start/Enter
key during the process.
Once you change the current value, store it by
pressing
Start/Enter
button again.
To stop discharging press
Batt type/Stop
key
once. The audible sound indicates you at the end
of process.
DEC INC
Batt type
stop
Start
Enter
`>3seconds`
DEC INC
battery
type
elapsed
time
discharge
current
battery
voltage
discharge
capacity
B8+ has a data storage and load program for your convenience. This feature can store
up to 10 battery data by number that represent the individual specification of batteries
you are using. They can be called back for the process of charging or discharging
without setting up the program again. To set up the parameter value in the program,
press
Start/Enter
key to make it blink then change the value with
Inc> or <Dec
key.
Discharging Pb battery
Discharging Pb battery
Save data program
13-14
15-16
17-18
19-20
21-22
23-24
25-26
27-28
29-30
31-32
33-34
35-36
The parameter value setting up in this screen does
not affect charge or discharge process. They only
represent the specification of the battery. The
following screens will automatically be displayed
exactly matched with the battery type you set up.
The example shows the battery pack of NiMH, 12
cells and 3000mAh of capacity.
Set up the charge current for manual charge mode,
or the current limit for automatic charge mode. Each
mode can be switched by pressing
Inc> and <Dec
button at the same time when the current field is
blinking.
Setting up discharge current and final voltage
Setting up the sequence of charge and discharge,
and the cycling number
Saving the data
Start
Enter
Type of
battery
capacity
voltage
date
number
Batt type
stop
Start
Enter
`>3seconds`
DEC
INC
DEC INC
DEC INC
DEC INC
DEC
INC
DEC INC
DEC INC
Start
Enter
`>3seconds`
Save data program
24
25