background image

E_MH_Mounting_instructions_Skylux_Climaglide_10mm_carrier_system

10/09/2021

2/16

Safety

Take the necessary and required safety precautions, such as safety nets and lifelines when installing from the 

outside, safety goggles, gloves, hard hat, etc.

Do not step on the glass.

Falling from height

•  When using ladders to go on the roof:

 - 

Ladder in good condition?

 - 

Set up correctly at an angle of 75°?

 - 

Secured below and on top against moving?

 - 

Don’t take heavy material with you on the ladder (3-point contact rule)! If possible, 

     use a crane to lift the material.

•  If you are going on the roof, make sure there is a walking surface that is wide enough and that  

  supports on the beams of the lower structure.

•  When using an aerial work platform: always wear and secure your harness (mandatory)! Leaving  

  the cage is forbidden. 

•  Never walk backwards on a roof, always walk forwards.

•  Make sure there’s enough light in the working zone.

Low-hanging obstacles and falling loads

•  Forbidden to walk under or within a radius of 1 m of a hanging or lifted load.

•  Demarcate the danger zone below the zone where there is a risk of material falling down    

  during the installation of the veranda.

•  It’s prohibited to enter these danger zones during construction. 

Crushing hazard

•  All working tools are in good condition, provided with a valid CE label and all necessary safety  

  regulations. These cannot be removed.

•  People who use these working tools are educated for this purpose. Protections are always   

  present on all working tools. They are in good condition and need to be set correctly. 

Tripping/falling

•  Safety is key and it begins with order and tidiness. Clean everything immediately, leave nothing  

  lying around. 

•  Trash needs to be sorted. 

•  Be cautious with electric cables (danger of tripping/falling). Never walk backwards! 

•  Make sure there’s enough light in the working zone.

Summary of Contents for Climaglide

Page 1: ...CANOPY Climaglide Mounting instructions carrier system 10 mm EN Art N 80574...

Page 2: ...ckwards on a roof always walk forwards Make sure there s enough light in the working zone Low hanging obstacles and falling loads Forbidden to walk under or within a radius of 1 m of a hanging or lift...

Page 3: ...e to your body as possible Parts of more than 25 kg must be lifted with at least 2 persons Personal protective equipment Work clothes safety shoes and helmet are mandatory for everyone Lifeline and ha...

Page 4: ...ND PARTS p 5 DRAWING p 6 USE AND VERSIONS p 7 GENERAL INSTALLATION TIPS p 8 MEASURING YOUR GLASS SLIDING PARTITION p 9 GLASS PLATES SIZES p 10 SPECIFIC INSTALLATION TIPS p 11 16 UPPER RAIL p 11 SIDE P...

Page 5: ...4 glass panels CGT510 Upper rail for 5 glass panels CGB3 Bottom rail for 3 glass panels CGB4 Bottom rail for 4 glass panels CGB5 Bottom rail for 5 glass panels CGL10 Side profile CGPL10 Carrier profil...

Page 6: ...09 2021 6 16 Drawing B1 B4 B5 CGSH sliding lock CGT Upper rail CGL10 side profile CGPL carrier profile CGB bottom rail B3 B1 Upper rail page 11 B2 Side profile with sliding lock page 12 B3 Side profi...

Page 7: ...sliding elements can be parked either to the left L or to the right R With a double system half the sliding elements are set to the left half to the right The bottom rail is pre drilled twice beneath...

Page 8: ...lower rail on the inner floor but 2 mm lower If you install the rail more than 2 mm lower please note that you will need to adjust the glass height In any case always make sure that the bottom rail do...

Page 9: ...parking side against which the glass sliding partition is installed must have at least the same depth Determining the dimensions Measure the width Bp between the posts Measure the height Hg from sill...

Page 10: ...t of the glass is 80 kg where X is the number of panels Below is a calculation example to clarify this Given A single system CG 303 L 10 with a total width Bp of 2975 mm and an Hg of 2150 mm This glas...

Page 11: ...approximately 70 cm and 4 cm from the ends Give each hole a chamfer so that the screw head is sunk Use countersunk screws to secure the profile not supplied In the case of the GX gutter Climalux alway...

Page 12: ...ll the lower rail with 6 mm to 4 cm from the ends and also with a spacing of approximately 70 cm in the indication lines between the outermost tracks Give each hole a chamfer so that the screw head is...

Page 13: ...and down mounting block CGCAL10U CGCAL10D First position the side profile on the parking side and centered above the outermost track Then screw the profile to the stanchion Use short screws for this s...

Page 14: ...make sure the side of the carrier profile is aligned with the side of the glass plate First push the carrier profile manually on the glass as far as possible Tap the carrier profile into the glass pl...

Page 15: ...ermost track The first sliding element is now positioned Check if the sliding element stands perfectly straight and horizontal If not the rail and the upper track must be aligned Repeat this procedure...

Page 16: ...just the position so that the lock enters the opening of the carrier profile Also test the locking positions of the other sliding elements For the seal against rainwater we recommend finishing the low...

Reviews: