E_MH_Mounting_instructions_Skylux_Climaglide_10mm_carrier_system
10/09/2021
8/16
General installation tips
Please read this manual carefully.
Installation must be carried out by people with sufficient technical knowledge and experience of constructions.
The fitter must take the necessary safety precautions during installation, such as the use of scaffolding and
personal protective equipment (safety shoes, hard hat, gloves, safety goggles, etc.) in order to work in safe
conditions. During construction, adequate precautions should be taken to ensure the stability of the unfinished
construction.
Fixing materials
The fixing materials required are chosen by you depending on the base. The screws and plugs for screwing the
profiles into the sill, the stanchions or the gutter profiles are not included. Use custom stainless steel countersunk
screws. Make sure the base and walls to which the unit is to be anchored are sufficiently strong. The fitter must
personally decide which fixing materials are suitable for the load and the base to which the unit is to be secured. In
case of doubt, we recommend that you contact your fixing materials supplier or a specialized engineering office.
Lower rail
We recommend not to install the lower rail on the inner floor, but 2 mm lower.
If you install the rail more than 2 mm lower, please note that you will need to adjust the glass height.
In any case, always make sure that the bottom rail does not lean to the inside.
Skylux is not responsible for installation and for the fixing materials used.
Conditions and warranty
The warranty becomes invalid if the installation instructions below are not followed. Failure to follow these
instructions and/or the use of other parts may adversely affect the safety and life of the product. Deviations are
not permitted without the written permission of the manufacturer. Our installation manual is based on our latest
knowledge and technology status. We cannot be held liable for any incomplete information. Always check whether
our product is suitable for your use.
Since our product is processed and assembled outside of our supervision, any damage cannot be attributed to
Skylux. The fitter must bear in mind the specified dimensions of the glazing and the wind load in accordance with
applicable standards.
The manufacturer reserves the right to make technical changes without prior verbal or written notice. Skylux
reserves the right to amend this manual without prior notice. Changes in the installation instructions or to the
product carry no right to compensation or exchange of parts.
The most recent version of this manual can be consulted at any time at www.skylux.be.