10/09/2021
13/16
E_MH_Mounting_instructions_Skylux_Climaglide_10mm_carrier_system
Side profile (CGL10) + side profile with sliding lock (CGSHS)
Needs to be sawn to the precise length on the construction site. Make sure the milled-out opening is facing
downwards. For centering side profile (CGL10) use upper and down mounting block (CGCAL10U, CGCAL10D).
First position the side profile on the parking side and centered above the outermost track. Then screw the profile
to the stanchion. Use short screws for this, so that the water discharge pipe is not pierced. Screws should have a
chamfered head (max. diameter of the head is 10,4 mm). Do the same against the other stanchion, but centrally
above the innermost track.
CGCAL10U
CGCAL10D
side profile with sliding lock
CGHS
side profile
CGHL10
lower rail
CGB
park side