Shown on the right is an
overall view of a completed
garage door opener system
installed on a sectional door.
The arrangement is similar for
a one-piece door (except for
differences described later in
this manual).
-4-
1. READ AND FOLLOW ALL INSTALLATION
INSTRUCTIONS.
2. Check with the door manufacturer to determine
if additional reinforcement is required to support
the door prior to installation of the garage door
opener.
3. Install garage door opener only on a properly
balanced garage door. An improperly balanced
door could cause serious injury. Have a qualified
service person make repairs to garage door
cables, spring assemblies, and other hardware
before installing the opener.
4. Remove all ropes and disable all locks connected
to the garage door before installing opener.
5. If possible, install the door opener 7 feet or more
above the floor. Mount the emergency release
handle 6 feet above floor.
6. Do not connect the opener to source of power
until this manual instructs you to do so.
7. Locate the wall console or wall button:
I. Within sight of the garage door
II. Out of reach of children at minimum height of
5 feet
III.Away from all moving parts of the door
8. Place Entrapment Warning Label on wall next
to garage door wall control
9. Place manual release / safety reverse test label
in plain view on inside of garage door.
10.Upon completion of the installation, the door
must reverse when it comes in contact with a
1-1/2" high object (or a 2 X 4 laid flat at the
center of the door) on the floor and when the
infrared safety beam is blocked.
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
WARNING
To reduce the risk of severe injury or death: