26
SJ12, SJ16
213721AAA
Section 3 – Familiarization
General components
3.4-7 Pothole protection device
1
Pothole protection device
: This device
consists of a set of mechanically actuated
steel weldments located under the base.These
weldments will automatically deploy for reduced
ground clearance when elevating the MEWP.
If the pothole-protection device has not fully
deployed when the MEWP is in the elevated
travel position the drive function will be disabled.
WARNING
Crushing Hazard. Personnel on the ground must
stay away from the pothole protection device. If
you do not obey, there is a risk of death or serious
injury.
3.5 General components
3.5-1 Circuit breaker and diagnostic
switch
Refer to
Figure 02
for the location of the circuit
breaker/diagnostic switch.
1
2
3
1
Diagnostic switch
The diagnostic switch is used during MEWP
servicing to diagnose MEWP operation.
2
Power-overload circuit breaker
If a power overload occurs, the circuit breaker
opens. Push the circuit breaker to reset the
circuit.
3
Circuit-grounding circuit breaker
If a positive circuit grounding occurs, the circuit
breaker opens. Push the circuit breaker to reset
the circuit.
WARNING
Do not use the diagnostic switch when there are
personnel on the platform. The MEWP may move
when you engage the diagnostic switch. If you do
not obey, there is a risk of death or serious injury.
F
A
M
IL
IA
R
IZ
A
T
IO
N
1
Summary of Contents for SJ12
Page 1: ...OPERATION MANUAL VERTICAL MAST 213721AAA September 2019 ANSI CSA SJ12 SJ16...
Page 4: ...4 SJ12 SJ16 213721AAA Notes...
Page 8: ...8 SJ12 SJ16 213721AAA Notes...
Page 14: ...14 SJ12 SJ16 213721AAA Notes...
Page 20: ...20 SJ12 SJ16 213721AAA Notes...
Page 58: ...58 SJ12 SJ16 213721AAA Notes...
Page 64: ...64 SJ12 SJ16 213721AAA Notes...
Page 80: ...80 SJ12 SJ16 213721AAA Notes...
Page 82: ...82 SJ12 SJ16 213721AAA Notes...
Page 83: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING...
Page 84: ...www skyjack com...