50
SJ12, SJ16
213721AAA
Section 5 – Operation
MEWP shutdown
5.9 MEWP shutdown
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
1.
Select a reasonably well-protected location to
park the MEWP. This location must have a firm,
level surface, clear of obstructions, and traffic.
2.
Fully lower the platform.
3.
Push the
emergency-stop
button.
WARNING
Fall Hazard. Use the three points of contact
principle when you use the MEWP to enter or exit
the platform. If you do not obey, there is a risk of
death or serious injury.
4.
Exit the platform.
5.
Turn the
off/platform/base key
switch to the
off position
on the base control console and
remove the key.
6.
Push the
emergency-stop
button.
7.
Turn the
main power disconnect
switch to the
off position
.
Summary of Contents for SJ12