38
Replacement Procedures
Service Manual
SKOPE TME650/1000
Condenser
Fan
The condenser fan motor, blade and mounting plate can be removed from
the refrigeration unit as a complete assembly.
To remove and replace the condenser fan blade
To remove and replace the condenser fan motor
1. Disconnect the chiller from the power supply.
2. Unscrew the mounting
plate fixing screws and
lift the mounting plate out
and up from the unit.
Note:
The mounting
plate has a tab slot at the
base of it.
3. Remove and replace the fan blade.
4. Reassemble and refit the refrigeration unit.
1. Remove the fan assembly and fan blade (see steps 1 - 3 above).
2. Open the unit junction
box (see page 36). Trace
the condenser fan flex to
the unit junction box and
detatch the condenser
fan wires (black and blue
from the fan capacitor,
brown and green earth
from the terminal block).
Withdraw the flex from
the unit junction box.
3. Remove the perimeter screws from around the fan motor to detach it from
the mounting plate and finger guard.
4. Fit the replacement fan motor to the mounting plate, refit the fan blade and
refit the assembly to the shroud. Replacements do not require
reprogramming as the speed is already set at the factory.
5. Feed the condenser fan flex through to the unit junction box and reattach
the wires. Refer to the wiring diagram (page 10) for wiring details.
6. Close the unit junction box and refit the refrigeration unit.