Installation
User Manual
SKOPE OD460
Enclosed installations
Enclosed installations must have the following minimum clearances around
the cabinet, and include the following features:
75mm behind the cabinet.
An air guide must be used to ensure all refrigeration exhaust air is
directed up and away from the cabinet.
The air guide must also ensure the air exhaust outlet cannot be blocked
by product or other items above the cabinet.
Refrigeration exhaust air must
NOT
be allowed to run horizontally across the
top of the cabinet, as it may be pulled down into the cabinet interior.
30mm
(rear spacer)
60mm
(min)
60mm
(min)
200mm
(min)
Free-standing installation ventilation requirements
Air
intake
Front
Back wall
Exhaust air
Exhaust air
Air guide
Enclosure ceiling
Air intake
Front
Enclosed installation ventilation
Exhaust air
Exhaust air must
NOT
run across
top of cabinet
Enclosure
back wall
75mm
(min)
Exhaust air
Exhaust air
Air
intake
Front
Enclosure ceiling
Air guide
Enclosure
back wall
Exhaust air
must
NOT
run across
top of
cabinet
Enclosed installation ventilation requirements