PG600/1300VC

Vertical Gastronorm Integral Chiller

SKOPE PEGASUS

PG600VC

PG1300VC

 

Summary of Contents for PEGASUS 1300VC

Page 1: ...Installation and Operating Instructions MAN8825 Rev 2 0 July 2007 edition PG600 1300VC Vertical Gastronorm Integral Chiller SKOPE PEGASUS PG600VC PG1300VC ...

Page 2: ...RINGEMENT The SKOPE trade mark on this product is infringed if the owner for the time being does any of the following Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Applies any other trade mark to the product Adds to th...

Page 3: ...ing Instructions 1 INSTALLATION 1 1 Safety Information 4 1 2 Positioning the Chiller 5 1 3 Shelving 7 1 4 Door Lock 8 2 OPERATION 2 1 Cabinet Operation 9 3 SERVICING 3 1 Interior Lighting 10 3 2 Cleaning 11 3 3 Contact Addresses 12 TABLE OF CONTENTS ii ...

Page 4: ... placing objects up against the refrigeration unit Do NOT probe any opening Only use this appliance with voltage specified on the rating label Ensure adequate ventilation of the SKOPE refrigeration system Be careful not to touch moving parts and hot surfaces Regulations require that all electrical work be carried out by authorised persons For your own safety and that of others ensure this is done ...

Page 5: ...sitioned on a level surface for the door s to shut and seal correctly and to prevent the condensate tray from overflowing Adequate allowance should be made for door opening Warning Heat dispersion and ventilation of the refrigeration unit cannot be overstressed The air surrounding the condenser must not exceed 40 C Power Supply The chiller is supplied with a 1 8m flexible power cord and plug which...

Page 6: ...geration unit Never store cardboard cartons or other items on top of the refrigeration unit When positioning the cabinet a gap of at least 200mm must be left above the refrigeration unit The cabinet can be positioned hard against a back wall however a gap of 50mm is recommended to prevent moisture build up see Figure 1 below Figure 1 Ventilation and Airflow 200 mm 50mm Wall Ceiling Airflow Front o...

Page 7: ...y 1 1 or 2 1 Gastronorm trays To fit the shelving 1 Unpack the shelving items from inside the cabinet 2 Establish the desired position for each of the shelves based on the height of the product intended to go on each shelf 3 Fit the stainless steel tray slides into the corresponding slots in both the front and back support rails Each shelf requires two tray slides see Figure 2 below 4 Slide each w...

Page 8: ...ges etc for efficient operation of the chiller Leave an air space of at least 50mm above packages etc on the top shelf Do not allow products to overhang the front of the shelves as this will effect air flow and could prevent the door s from shutting Product must NOT be stored on the floor of the cabinet 1 4 Door Lock Each door has a key lock located at the top of the door on the same side as the h...

Page 9: ...will continue to circulate at all times The compressor will start after approximately one minute The compressor will switch off when the cabinet internal temperature reaches approximately 21 C and on again at approximately 18 C The electronic temperature display located on the front fascia panel will always display the current cabinet temperature Cabinet Lighting The cabinet interior lighting will...

Page 10: ...ht bulb 1 Disconnect the cabinet from the mains power supply 2 Reach inside the cabinet and remove the front panel of the intrerior light assembly by undoing both end screws 3 Unscrew the light bulb and replace with new bulb SKOPE part no ELL1945 Always ensure to use the correct wattage light bulb 4 Replace the front panel and reconnnect cabinet to the power supply Figure 5 Interior Light SERVICIN...

Page 11: ...mmended Condenser coil The condenser coil should be brushed clean once a month and blown clean by qualified service personnel every six months see Figure 6 below The condenser coil is located on top of the cabinet behind the front fascia panel To remove the fascia panel lift the panel up and place it on top of the refrigeration unit Caution Disconnect the cabinet from the mains power supply before...

Page 12: ...TED PO Box 1091 Christchurch NEW ZEALAND Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz Australia SKOPE AUSTRALIA PTY LTD A C N 000 384 270 PO Box 7543 Baulkham Hills B C NSW 2153 AUSTRALIA Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au SERVICING 3 ...