14
Operation
User Manual
SKOPE OD460
Temperature
Setpoint
The chiller is manufactured with a pre-set control temperature set point
which can be adjusted if required. SKOPE do not recommend that the set
point be changed unless absolutely necessary.
To view and adjust the temperature setpoint
Controller
Reset
To delete program modifications and reset the controller to SKOPE default
program or when a replacement controller is being fitted, a ‘Controller Reset’
must be performed.
To reset the controller
1. To view the setpoint: press and hold the
key for 2 seconds, until the
setpoint value flashes
2. To adjust the setpoint: press either the
and
keys to display the
required setpoint value.
3. Press the
key again to memorise
the new setpoint value. If this is not
done within 60 seconds, changes will
be lost and you will need to repeat the
above procedure.
1. Disconnect the cabinet from the power supply.
2. Press and hold the
key while
plugging the cabinet into the power
supply (may require two people). After
a few seconds the program mode ‘
bn0
’
is displayed. The controller must never
be left in program mode ‘
bn0
’ as failure
will occur.
3. Press the
or
keys to select
bn1
(SKOPE default program).
4. Immediately press the
key to
confirm the preferred program. If not
confirmed within 60 seconds the
cabinet will remain in program mode
‘
bn0
’ (and cause failure). If this occurs,
repeat the above procedure.