18
Maintenance
User Manual
SKOPE OD460
Troubleshooting
For questions about the electronic controller, see page 11. For problems
with the cabinet and refrigeration cassette, use the following table.
Problem
Possible Cause
Suggestions
• Chiller not operating
• No controller display
• Loss of power supply
• Isolating switch turned
off
• Check mains power
supply.
• Check isolating switch
(see page 16).
• Lights not on
• Night blind is down
• Raise the night blind.
• Light switched off
• Switch light on at
electronic controller
faceplate (see page 12).
• Lighting fault
• Arrange a service call.
• Blown cabinet fuse
• Arrange a service call.
• Power consumption is
higher than expected
• Refrigeration unit
operating too hot
• Clean the condenser coil
(see page 17).
• Ensure the cabinet has
good ventilation around
the refrigeration unit
(see page 5).
• Ensure the cabinet is
installed in a cool
location within operating
specifications (see
page 5).
• Product is too warm
• Restricted airflow to
cabinet
• Ensure product is not
blocking airflow slots.
• Ensure there is space
around individual
product pieces.
• Warm cabinet
temperatures
• Compressor operating
for long periods (more
than 1 hour)
• Blocked condenser
• Clean the condenser coil
(see page 17).
• Poor ventilation around
refrigeration cassette
• Ensure the cabinet is
installed in a cool
location within operating
specifications (see
page 5).