![Skope OD460 User Manual Download Page 12](http://html1.mh-extra.com/html/skope/od460/od460_user-manual_1289199012.webp)
12
Operation
User Manual
SKOPE OD460
Faceplate
Because the electronic controller plays such an important role, it’s helpful to
know the parts of the faceplate you may use.
9
10
11
1
2
4
3
15
14
13
12
8
7
6
5
No. Item Description
1
Mute (program):
Button. Mutes the audible controller alarm. Also used
for controller programming.
2
Aux (up):
Button. Press and hold to switch the lights on and off. Also
used for controller programming.
3
Set:
Button. Service use only. Used for controller programming
4
Defrost (down):
Button. Press and hold to initiate a manual defrost
cycle. Also used for controller programming.
5
Compressor:
Indicator. On when the compressor and condenser fan
are running. Flashes when activation of the compressor is temporarily
delayed.
6
Fan:
Indicator. On when the fans are operational.
7
Defrost:
Indicator. On when a defrost cycle is activated. Flashes when
the activation of the defrost is temporarily delayed due to procedures in
progress.
8
Aux:
n.a.
9
Alarm:
Indicator. Flashes in the event of alarms.
10
Clock:
Indicator. On when real time clock is enabled.
11
Light:
Indicator. On when the cabinet lighting is activated.
12
Service:
Indicator. Flashes in the event of malfunctions.
13
Display:
Indicator. Digital display of cabinet temperature or alarms.
Displays
nHt
during night mode. The temperature is what the sensor
inside the chiller detects, and not necessarily the product temperature.
However, they may be very close depending on how the controller is set
to sense temperature.
14
HACCP:
n.a.
15
Continuous Cycle:
Continuous cycle in progress (see page 13).