Fig.6
Charger operation
Charging the battery pack
Before using your PowerLuber for the first
time, the battery pack should be fully charged.
If the battery pack is installed in the
PowerLuber, remove it and follow “Charging
Procedure” below.
Lincoln chargers are designed to charge Lin-
coln Lithium batteries in 30-60 minutes de-
pending on the battery’s state of charge and
temperature.
Charging procedure
Make sure power circuit voltage is the
same as that shown on the charger specifi-
cation plate
.
1
Plug the charger into an appropriate outlet
before inserting battery pack.
2
Insert the battery pack into the charger. The
green (charging) light will blink continuously
indicating that the charging process has
started.
3
The completion of charge will be indicated by
the green light remaining ON continuously.
The pack is fully charged and may be used at
this time.
4
Disconnect charger from power source when
not in use.
!
Notice:
Do not
charge battery in air temper-
ature below +40° F
(4.5° C)
or above 104°
F
(+40° C)
.
Serious damage to battery can occur.
!
Notice
Vent slots in top and bottom of
charger must not be obstructed.
120/230 volts present at charging ter-
minals, which can cause electric shock or
electrocution.
Do not probe with conductive objects.
Failure to comply may result in serious
injury or death.
W A R N I N G
Indicator light operation
The.charge.is.complete.(Solid.green)
The.battery.is.being.charged.(flashing.green)
(Red.at.a.fast.rate).Replace.battery ..
The.charger.detected.a.week.or.damaged.bat-
tery ..Do.not.contineu.to.charge.battery .
Hot/cold.pack.delay .
The.charger.detected.a.battery.that.is.exces-
sively.hot.or.cold ..It.automatcially.starts.a.hot/
cold.pack.delay,.suspedngin.charging.until.the.
temperature.of.the.battery.has.normalized ..
After.this,.the.charger.automatically.switches.
to.the.batterh.charging.mode .
1850
1861
16
A &
A HYDRAULIC
800-992-9898