Prime the grease gun
Prime the cordless grease gun after each re-
fill or grease cartridge change.
Priming instructions
1
Open vent valve (
5
) (
† fig.1
,
pg. 11
).
2
Squeeze gun trigger until grease flows
from vent valve.
3
Close vent valve.
4
Press buttons “A” and “B” (
23
) at same time
for 5 seconds to delete any previous grease
readings and reset display (
22
) to 0
(† fig. 3)
.
5
Press button “A” (
23
) to display “Grease
Level Full” indicator.
Operation
Speed selection
When motor is not running,
push the le-
ver (
10
) (
† fig. 3
) until letter “L” or “H” is
completely visible in the window.
In case the lever is not completely
shifted/engaged,
hold the lever and toggle
the switch to engage gears.
High delivers
5 .5.ounces
(
0,162 l
) per min-
ute at
1,000.psi
(
68 bar
) back pressure.
Low delivers 3.5 oz.
(0, 103 l
) per minute at
1,000.psi
(
68 bar
) back pressure.
!
Notice
To prevent damage to transmis-
sion gears, motor must be completely
stopped before changing lever to “L” or
“H” (low or high) mode of operation.
LCD display and light
To.turn.display.
(
22
) and light
(† fig. 3)
“ON”,.
either:
1
Push.either.key ..
2
Gently.squeeze.the.trigger/switch .
To.turn.display.
(
22
)
.and.light.“OFF”:
1
Push and hold key “B” for 5 sec.
2
Wait 30 seconds for self shutoff.
!
Notice
Grease meter displays output only
if grease gun is adequately primed.
Fig. 3
10
23
22
13
A &
A HYDRAULIC
800-992-9898