Fig. 14
Pump without follower plate
Grease reservoir
empty
• Control cam (
3
) guides pivot bracket with
magnet (
1
) outward. Since there is no
grease resistance, bracket with
magnet (
1
) will stay outward in orbit C.
• Magnet (
1
) will align with low-level switch
and activate
LL
indicator on pump display.
C
2
1
D
3
Switching parts of low-level control for grease (when reservoir is empty).
1
Pivot bracket with round magnet.
2
Low-level switch
3
Control cam
C
Outer orbit of round magnet
D
Position of pivot bracket (LL activated)