Identification code P653S pump
Code example
P653S
-
4
-
X
-
L
-
F
-
24
-
2A
-
AS06
Pump mode, basic
Reservoir size and configuration
4 = 4 l, transparent plastic
8 = 8 l, transparent plastic
15 = 15 l, transparent plastic
20 = 20 l, transparent plastic
X = grease pump
L = low level control
BO = without follower
F = with follower
Power supply
24 = 24 V DC
AC = 110 - 240 V AC, 50 - 60 Hz.
Electrical cord and connections
1A DC:
– 33 ft.
(10 m)
cord, 7 conductors
2A DC:
– 33 ft.
(10 m)
cord, 7 conductors
– 33 ft.
(10 m)
cord, 4 conductors with
bayonet plugs for external pressure
switch or transducer
2A AC
– 33 ft.
(10 m)
cord, 7 conductors
- 4-pole square plug
2A1 = AC
– 33 ft.
(10 m)
cord, 7 conductors
- 4-pole square plug
– 33 ft.
(10 m)
cord, 4 conductors with
bayonet plugs for external pressure
switch or transducer
Pressure control, PCB setting.
AS01 – S08 - pressure switch
(† Jumper setting table)
AS09 – AS16 = pressure transducer (†
Jumper setting table)
Example: P653S-4XLF-24-2A-AS06:
Pump consists of the following:
24 V DC grease pump with follower
Four liter reservoir
Low-level control
Internal pressure switch
33 ft.
(10 m)
power cord
External pressure switch with 33 ft.
(10 m) cord
8
Summary of Contents for Lincoln P653S
Page 47: ...Fig 33 Pump with follower 54 53 52 51 50 49 48 47 46 45 44 41 42 43 47...
Page 50: ...Fig 35 Pump without follower 50 49 48 47 46 45 44 43 42 50...
Page 53: ...This page left intentionally blank 53...
Page 54: ...This page left intentionally blank 54...