3.3.2 Characteristics of oil supply unit
Ambient temperature . . . . . 0 °C to + 45 °C
Drive . . . . . . . . . . . . . Electrical
Motor and pump
Pump motor . . . . . . . . .
Motor type
Motor type
Rated motor output . . . . . .
2,2 kW
2,64 kW
Rated voltage . . . . . . . . . 230/400 V AC
265/460 V D/Y
Rated frequency. . . . . . . . 50 Hz
60 Hz
Rated speed . . . . . . . . . . 1 000 rpm
1200 rpm
Protection class . . . . . . . . IP55 Th.Cl. 155(F)
IP55 Th.Cl. 155(F)
Volumetric low, nominal
SAB 0/162
. . . . . . . 15 l/min
18 l/min
SAB 0/166
. . . . . . . 11 l/min
13.2 l/min
Hydraulic system
Operating pressure . . . . . . 50 bar
Admission pressure . . . . . . Max. 3.5 bar
Electrical system
Connector socket . . . . . . . . . . . . . . .DIN EN 175301-803-A
Mounting position: . . . . . . . . . . . . . .Vertical
Operating viscosity
(kinematic viscosity) . . . . . . . . . . . . . .25 to 2 000 mm
2
/s
1
)
Oil supply unit, complete, empty. . . . . . . .Approx. 110 to 120 kg
1) The effective operating viscosity of the lubricating oil
used must be adjusted to the specifications above (using
data sheet from oil manufacturer). The maximum per-
missible value of 2 000 mm
2
/s may only be exceeded
after consulting with the engine manufacturer.