- 78 -
951-181-014-EN
Version 16
EN
12. Repairs
•
Guide the cable through the cable duct
(19) on the terminal box (8).
•
Mount the cable in the terminal box (see
connection diagram in the Technical data)
•
Tighten the cable duct (19) on the termi-
nal box (8) correctly again.
Tightening torque = 1.5 Nm ±
0.1
Nm
•
Firmly screw lid to terminal box by means
of the 4 screws (18).
•
Tigthen sensor fitting (21) on reservoir
lid.
Sensor M18 x 1.0 = 2 Nm ±
0.1
Nm
•
Place reservoir lid (1) on reservoir again
and lock it on the two lockings (17).
Replacement of capacitive sensor Fig 13
Exi
17
17
1
8
19
18
20
21
22
23
20
R