4
EN
4. Technical data
- 33 -
951-181-014-EN
Version 16
Part number
Designation on the type identification plate
Motor Reservoir Sensor
Ambient
temperature range
Explosion protection marking
min.
max.
Seawater-resistant version
655-46716-1 P205-M075-10XL -2K7/1KR-460 KAP. EEX
3
7
A
- 20 °C + 50 °C
II 3D Ex h IIIC T120°C Dc
655-46716-2 P205-M075- 5XL -1K6- 24 KAP. EEX
7
3
A
- 20 °C + 55 °C II 2G Ex h IIB T4 Gb
655-46716-3 P205-M075-10XYN -1KR-400 EEX
2
8
- 20 °C + 40 °C II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T120°C Db
655-46716-4 P205-M075- 5XL -2K6- 24 KAP. EEX
7
4
D
- 20 °C + 55 °C II 2G Ex h IIB T4 Gb
655-46716-6 P205X-M075- 5XL -2K6-440 KAP.EEX VN1410
5
1
D
- 20 °C + 40 °C II 2G Ex h IIB T4 Gb II 2D Ex h IIIC T120°C Db
655-46716-7 P205-M075- 5XL -2K6- 24 KAP. EEX (-30°C)
7
2
B
- 30 °C + 55 °C II 2G Ex h IIB T4 Gb
655-46716-8 P205-M075- 5XL -2K6- 230 KAP. EEX
10
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
655-46716-9 P205-M075- 5XL -2K6- 230 KAP. EEX
10
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
655-46848-1 P205-M075- 5XL -2K6-230 KAP. EEX (-30°C)
10
2
B
- 30 °C + 55 °C II 2G Ex h IIC T4 Gb
655-46848-3 P205-M075- 5XL -2K6- 230 KAP. EEX
11
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
655-46848-4 P205-M075- 5XL-2K6-230 KAP.EEX
10
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
655-46848-6 P205-M075- 5XYN -1K5/1K7-400 EEX
4
5
- 20 °C + 40 °C II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T120°C Db
655-46848-7 P205-M075- 5XL-2KR-230 KAP.(EL.IECEX) EEX
12
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
655-46848-8 P205-M075- 5XL-2KR-230 KAP.EEX
10
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
655-47109-1 P205-M075-5XYN -2K5-460 KAP.EEX
1
5
- 20 °C + 40 °C II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T120°C Db
655-47109-2 P205-M075- 5XL -2K6- 24 KAP. EEX
7
4
D
- 20 °C + 55 °C II 2G Ex h IIB T4 Gb
655-47109-3 P205-M075- 10XL -1K7- 400 KAP. EEX
2
7
A
- 20 °C + 40 °C II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T120°C Db
655-47109-4 P205-M075-5XL-2K6-380 KAP. EEX VN1410
14
4
D
- 20 °C + 40 °C II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T120°C Db
655-47109-5 P205-M075- 5XYN -1K6-440 EEX RAL 7031
5
10
-
- 20 °C + 40 °C II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T120°C Db
Unpainted version
655-46716-5 P205-M075- 5XL -2K6- 24 KAP. EEX GEDA
8
4
D
- 20 °C + 55 °C II 2G Ex h IIB T4 Gb
655-46848-2 P205-M075- 5XL -2K6-230 KAP. EEX GEDA X
10
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
655-46848-9 P205-M075- 5XL-2KR-230 KAP.EEX GEDA X
13
4
D
- 20 °C + 55 °C II 2G Ex h IIC T4 Gb
The indicated temperature range of the pump presupposes the suitability of the lubricant used for the respective actually existing ambient tempera-
ture. Using a lubricant not suitable for the actual ambient temperature may, in case of low temperatures, result in a blockade of the pump due to a too
high lubricant viscosity. The ignition temperature of the lubricant must lie at least 50 K over the maximum surface temperature of the components.
Summary of Contents for 655-41261-1
Page 84: ...EN Annex 84 951 181 014 EN Version 16 Declaration of conformity of EDRN motor make SEW...
Page 85: ...15 EN Annex 85 951 181 014 EN Version 16 Declaration of conformity of DFR motor make SEW...
Page 86: ...EN Annex 86 951 181 014 EN Version 16 Declaration of conformity of BA AP80 motor make ELNOR...
Page 88: ...EN Annex 88 951 181 014 EN Version 16 Declaration of conformity of motor make CEMP...
Page 89: ...15 EN Annex 89 951 181 014 EN Version 16 Declaration of conformity of motor make CEMP...
Page 90: ...EN Annex 90 951 181 014 EN Version 16 Declaration of conformity of motor make CEMP...
Page 91: ...15 EN Annex 91 951 181 014 EN Version 16 Declaration of conformity of terminal box make Bartec...