- 20 -
951-181-014-EN
Version 16
EN
1. Safety instructions
1.26 Residual risks
Residual risk
Possible in life cycle
Prevention/ remedy
Personal injury/ material damage due to
falling of raised parts
A B C
G H K Keep unauthorized persons away. No people may remain under suspended
loads. Lift parts with adequate lifting devices.
Personal injury/ material damage due to
tilting or falling of the product because of
non-observance of the stated tightening
torques
B C
G
Observe the specified tightening torques. Fix the product only to components
with sufficient load capacity. If no tightening torques are stated, apply tightening
torques according to the screw size characteristics for 8.8 screws.
Personal injury/ material damage due to
electric shock in case of damage to the
connection cable
B C D E F G H
Check the connection cable with regard to damages before the first usage and
then at regular intervals. Do not mount cable to moving parts or friction points. If
this cannot be avoided, use spring coils respectively protective conduits.
Personal injury/ damage to material due
to spilled or leaked lubricant
B C D
F G H K
Be careful when filling the reservoir and when connecting or disconnecting lubri-
cant feed lines. Always use suitable hydraulic screw connections and lubrication
lines for the stated pressures. Do not mount lubrication lines to moving parts or
friction points. If this cannot be avoided, use spring coils respectively protective
conduits.
Life phases:
A = transport, B = installation, C = initial start-up, D = operation, E = cleaning, F = maintenance, G = fault, repair, H = shutdown, K = disposal
Summary of Contents for 655-41261-1
Page 84: ...EN Annex 84 951 181 014 EN Version 16 Declaration of conformity of EDRN motor make SEW...
Page 85: ...15 EN Annex 85 951 181 014 EN Version 16 Declaration of conformity of DFR motor make SEW...
Page 86: ...EN Annex 86 951 181 014 EN Version 16 Declaration of conformity of BA AP80 motor make ELNOR...
Page 88: ...EN Annex 88 951 181 014 EN Version 16 Declaration of conformity of motor make CEMP...
Page 89: ...15 EN Annex 89 951 181 014 EN Version 16 Declaration of conformity of motor make CEMP...
Page 90: ...EN Annex 90 951 181 014 EN Version 16 Declaration of conformity of motor make CEMP...
Page 91: ...15 EN Annex 91 951 181 014 EN Version 16 Declaration of conformity of terminal box make Bartec...