background image

Disassembling

To disassemble the smoke alarm, take a screw driver and push it into the 

moun ng hole. Then, turn the smoke alarm counterclockwise to remove 

it from the moun ng bracket. 

Recycling and disposal 

        The WEEE symbol means that this product and ba eries 

        must be disposed separately from other household waste. 

        When they reach their end of life, take them to a designated 

waste collec on point in your area to guarantee a safe disposal or 

recycling. Protect the environment, human health and natural resources! 

Membership in eco-organisa on Ecologic.  

Service

Cer fied by AFNOR Cer fica on (www.afnor.org)

Helpline number: +86 574  83011532

The CE mark affixed to this product confirms its compliance with the 

European Direc ves which apply to the product and, in par cular, its 

compliance with the harmonized specifica ons of standard EN 

14604:2005 rela ng to Construc on Products Regula on 305/2011. The 

NF – DOMESTIC FIRE SAFETY mark provides assurance as to safety and 

consistent quality inspected by experts. Through its rigorous and 

exhaus ve inspec ons (holder's quality management system, product 

inspec ons, audits and monitoring tests, etc.), the NF mark represents a 

comprehensive guarantee for consumers that the cer fied products are 

compliant. The NF – DOMESTIC FIRE SAFETY mark confirms the product's 

compliance with cer fica on rules NF 292.

-6-

Essen al cer fied features covered by the NF mark

  Type of moun ng                            Ceiling, wall
  Main power supply                           Internal to device (ba ery)
  Ba ery dura on                              10 years, not replaceable
  Individual alarm indicator                   Yes
  Installa on in recrea onal vehicles         Yes
  Alarm silence facility                         Yes
  Ba ery fault-forwarding at night            Yes

Summary of Contents for GS546

Page 1: ...anism We recommend to test the smoke detector manually at least once every three months by using the test facility If the smoke alarm func ons correctly it will generate a loud beep Due to the loudness of the alarm make sure that you always stand at arm s length distance from the unit when you are tes ng If the smoke alarm does not generate an acous c signal the smoke alarm must be replaced immedi...

Page 2: ...gs of corridors Rooms with sloping ceilings Ceiling inclina on is 20 to the horizontal Smoke alarms must be installed at least 0 5 m and at most 1 m from the ceiling top Par al roof slopes If the flat ceiling is 1m wide consider as ceiling inclina on is of 20 If the flat ceiling is 1m wide consider as flat ceiling Rooms with subdivided ceilings Height of the subdivisions is 0 2 m Beams without consid...

Page 3: ...ves which apply to the product and in par cular its compliance with the harmonized specifica ons of standard EN 14604 2005 rela ng to Construc on Products Regula on 305 2011 The NF DOMESTIC FIRE SAFETY mark provides assurance as to safety and consistent quality inspected by experts Through its rigorous and exhaus ve inspec ons holder s quality management system product inspec ons audits and monitor...

Page 4: ... Produktmodell 6 Produk yp 7 Hardwareversion 8 Vertragsversion 9 So wareversion 10 ID Code Wartung Dieser Rauchwarnmelder ist mit einem Selbs estmechanismus ausgesta et Wir empfehlen den Rauchwarnmelder mindestens einmal alle drei Monate manuell auf der Prü aste zu testen Wenn der Rauchwarnmelder rich g funk oniert ertönt ein lauter Piepton Aufgrund der Lautstärke des Alarms sollten Sie beim Teste...

Page 5: ...die korrekte Ak vierung Ihres Rauchwarnmelders durch Drücken der Prü aste Wird kein Ton erzeugt wurde der Rauchwarnmelder nicht rich g ak viert und sollte nicht verwendet werden Montage Setzen Sie die Montagepla e auf die gewünschte Einbaustelle und markieren Sie wo die Löcher gebohrt werden sollen Bohren Sie zwei Löcher mit einem Durchmesser von 5 Millimetern Schieben Sie die Dübel in die Löcher ...

Page 6: ...ns mmung mit den für das Produkt geltenden europäischen Richtlinien und insbesondere die Übereins mmung mit den harmonisierten Spezifika onen der Norm EN 14604 2005 zur Bauproduktverordnung 305 2011 Das NF DOMESTIC FIRE SAFETY Zeichen gibt Sicherheit in Bezug auf Sicherheit und gleichbleibende Qualität die von Experten geprü wird Durch seine strengen und umfassenden Inspek onen Qualitätsmanagements...

Page 7: ...r www china siter com Iden fica on DAAF www marque nf com 4 5 Neutralisa on d alarme Si le détecteur de fumée a détecté de la fumée et est entré en mode alarme vous pouvez neutraliser le son de l alarme pendant au moins 5 minutes et au plus 15 minutes en appuyant sur le bouton de test Le détecteur de fumée revient alors automa quement au mode de fonc onnement normal S il y a encore des par cules de...

Page 8: ...rizontale Les détecteurs de fumée doivent être installés à au moins 0 5 m et à au plus 1 m du plafond Toiture par elle Si la par e horizontale du plafond est d 1 m de large on peut supposer une inclinaison du plafond 20 Si la par e horizontale du plafond est 1 m de largeur on peut supposer un plafond horizontal Pièce avec plafonds subdivisés La hauteur des subdivisions est de 0 2 m les poutres ne ...

Page 9: ...nes qui lui sont applicables en par culier sa conformité aux spécifica ons harmonisées de la norme EN 14604 2005 en regard du règlement 305 2011 rela f aux produits de construc on La marque NF appliquée aux Détecteurs Aver sseurs Autonomes de Fumée DAAF c est l assurance de la sécurité et d une qualité constante contrôlées par des spécialistes Par ses contrôles rigoureux et exhaus fs système de man...

Reviews: