The sequence function executes prepositioning of the pan, tilt, zoom, and focus features in a
certain sequence for a camera. The HSD820 series cameras support up to eight sequence
lines. Up to 64 points can be specified for each sequence line.
Note: Before setting this function, users must set at least two preset points.
To program a sequence line
1
On the PTZ tab, click Sequence in the menu on the left.
2
Under Sequence setting, click Edit.
3
Click to open the Sequence line list on the Sequence Set page, and then select the
number of the line (1-8) you wish to program.
4
Set up each sequence point in the desired order by assigning a preset from the Name
list, and specifying a dwell time (0-255) and speed (0-14) in the corresponding text
boxes.
For more information on dwell times, see below.
Sequence points 1-64 can be accessed through the Pre page and Next page buttons.
5
Click Save.
To execute a defined sequence
1
On the PTZ tab, click Sequence in the menu on the left.
2
Under Sequence run, select the number of the sequence line to be run from the
Sequence line list.
3
Press Go.
The camera starts moving from preset to preset sequentially as programmed.
To view the cruise in full-screen mode, right-click the live view pane, and then select
fullscreen.
The sequence is continuously repeated.
To stop running a sequence
● Drag the (red) mouse pointer across the live view pane in any direction.
The current sequence stops and is no longer repeated.
Dwell time
The dwell time is the duration time the dome remains at a sequence point. The range is from
0 to 255 seconds. The dome will go to the next sequence point when the dwell time expires.
PTZ&IMAGE