21
Estimations based on 40 Degrees F and 65% relative humidity. Estimations not guaranteed.
Bin
Bu. Cap.
Fan
20%
22%
24%
26%
Dia.(ft.)
Per Ft. Depth
Size
1 CFM/Bu 2 CFM/Bu 3 CFM/Bu 4 CFM/Bu
15
140
(1) 5HP Axial
20
14
11
9
(1) 5HP Axial
20
14
10
8
(1) 7 1/2HP Axial
20
14
10
8
(1) 5HP Axial
20
13
9
8
(1) 7 1/2HP Axial
20
14
10
8
(1) 10HP Axial
20
15
11
9
(1) 10HP Cent
20
16
12
9
(1) 5HP Axial
19
12
8
6
(1) 7 1/2HP Axial
20
13
9
7
(1) 10HP Axial
20
14
10
7
(1) 10HP Cent
20
15
10
8
(1) 20HP Cent
20
17
12
10
(2) 10HP Cent
20
17
14
11
(1) 7 1/2HP Axial
19
11
8
6
(1) 10HP Axial
20
12
9
7
(1) 10HP Cent
20
13
9
7
(1) 20HP Cent
20
16
12
8
(2) 5HP Axial
20
14
10
8
(2) 7 1/2HP Axial
20
14
10
8
(2) 10HP Cent
20
17
13
10
(1) 7 1/2HP Axial
18
10
7
5
(1) 10HP Axial
19
11
7
5
(1) 10HP Cent
20
12
8
6
(1) 20HP Cent
20
14
10
7
(2) 5HP Axial
20
13
9
7
(2) 7 1/2HP Axial
20
14
10
8
(2) 10HP Axial
20
16
12
9
(2) 10HP Cent
20
16
12
10
(2) 20HP Cent
20
18
14
11
(1) 10HP Axial
17
9
6
5
(1) 10HP Cent
18
10
6
5
(1) 20HP Cent
20
12
9
6
(2) 5HP Axial
20
12
8
6
(2) 7 1/2HP Axial
20
13
9
7
(2) 10HP Axial
20
14
11
8
(2) 10HP Cent
20
16
12
9
(2) 20HP Cent
20
17
13
10
(1) 10HP Axial
15
8
6
4
(1) 10HP Cent
16
8
5
4
(1) 20HP Cent
20
11
8
5
(2) 7 1/2HP Axial
20
12
8
6
(2) 10HP Axial
20
12
9
7
(2) 10HP Cent
20
14
10
7
(2) 20HP Cent
20
16
12
9
(2) 10HP Cent
20
11
8
6
(2) 20HP Cent
20
14
10
8
(3) 20HP Cent
20
17
12
9
(2) 20HP Cent
18
10
7
5
(3) 20HP Cent
20
14
10
7
(14-24)
(14-20)
(12-18)
(12-15)
30
18
Estimated Drying Time (Days)
42
1,108
48
1,809
21
278
33
684
205
565
Low Temp Drying Guide
36
844
Initial Fill Depth (ft.)
24
375
27
458