13. Slide the Sifting module back into the device and lock
both drawers
31
,
37
(image 51).
14. Lower the Flexible tube with the sieve flange
28
and
connect with sieve
30
, put on the clamping ring
29
, and
lock it with a locking pin.
15. Close the door of the Sifting module.
31
37
Image 51. Insert both drawers with the Sifting module
to the PHS inside.
B. CLEANING THE POWDER FEEDING SCREW
For these activities you will need:
Allen key 5 mm
G
(from the box with additional accessories)
1. Operate only when the power is off! Also, switch on the E-STOP button
19
on the Control Panel to cut off power from
the internal components of the machine.
2. Remove both grids from the Chambers
1
,
2
. Pull out first the grid of the Powder Chamber and then, by lifting in the
dedicated place, the grid from the Fine Dust Chamber (image 52).
1
2
Image 52. Lifting of grids from PHS Powder Chambers.
3. Using an Allen key 5 mm, unscrew the four screws of the Powder Feeding Screw guard in the Powder Chamber
22
and put it aside (image 53).
4. Use an Allen key to unscrew the one screw of the Powder Feeding Screw guard in the Fine Dust Chamber
24
and
put it aside (image 53).
X4
X1
22
24
2
Image 53. Unscrewing the Powder Feeding Screw guards in the chambers.
33 | POWDER HANDLING STATION Manual
Summary of Contents for POWDER HANDLING STATION
Page 2: ......