8. Powder emptying and cleaning process of the PHS device
1. After the sifting process is complete, open the door of the Sifting module and tapping the flexible tube of the Metal
container
34
.
2. Remove the locking pin and unfasten the Clamping ring on the Metal container
35
(image 35).
3. Lift and attach the Flexible tube with the flange
34
to the magnetic holders of the Metal container flange
33
(image
35). Put a clamping ring on the flange so that it does not fall on the Metal container
36
.
36
34
35
34
33
Image 35. Remove the pin and unfasten the clamping ring
on the Metal container.
Image 36. Attach the flange of the Metal container to the
magnetic holders.
4. Release the Drawer lock
38
and pull out the drawer with the Metal container
37
(image 37).
5. Remove the Metal container
36
with sifted powder from the pull-out drawer
37
(image 38).
37
38
37
36
Image 37. Unlocking the drawer of the Metal container.
Image 38. Removing the Metal container
with sifted powder from a drawer.
6. Slide the drawer
37
with the new, empty container back into place (make sure the handle of the container is correctly
positioned) and lock the drawer with the drawer lock
38
.
7. Lower the Flexible tube with the container flange
34
, put on the clamping ring
35
, lock it with a locking pin.
8. Close the door of the Sifting module.
9. The device is ready for reuse.
10. When you finished work, and if you do not plan to
continue using the PHS device, press the E-STOP
Safety button
19
, to turn PHS OFF. To make sure
that the device has a power cut-off when you are not
planning to use it for a longer period of time unplug
power cable from the socket (image 39).
STOP
EM
ERGENCY
PRESS THE BUTTON
Image 39. Press the E-STOP button when you
no longer plan to use PHS.
POWDER HANDLING STATION Manual | 28