User Manual
EM303A General Purpose Inverter
54
6.2.5
Group F4: General Parameters of PID
No.
Function
Range
Unit
Default
Type
F4-00
PID Regular
Setting Mode
0: Numeric PID Setting
1: VS
2: IS
3: VF
4: IF
5: VP
0
〇
F4-01
PID Numeric
Setting
0.00~10.00 V
5.00
●
F4-02
PID Feedback
Channel
0: VF
1: IF
2: VS
3: IS
0
〇
F4-03
PID
Monitoring
Options
0: Voltage-V
1: Actual Physical Quantity (V*Display Coefficient)
0
〇
F4-04
PID Display
Coefficient
0.01~100.00
1.00
●
F4-05
PID Positive/
Negative
Setting
0: Positive Setting
1: Negative Setting
0
〇
F4-06
PID Output
Gain
0.00~100.00 %
100.00
●
F4-07
Proportion
Gain GP
0.00~100.00
0.40
●
F4-08
Integration
Time GTi
0.000~30.000 0.000:No Integration
S
10.000
●
F4-09
Differentiation
Time GTd
0.000~10.000 S
0.000
●
F4-10
Integration
Function Scale
0.00~100.00 %
100.00
●
F4-11
PID Positive
Output Limit
0.00~100.00 %
100.00
●
F4-12
PID Negative
Output Limit
0.00~100.00 %
0.00
●
F4-13
Menu Display
Control 1
Fd.
FC.
Fb. FA. F9. F8.
F7.
F6.
11111111
●
1 1 1 1 1 1 1 1
0
:
No Display
,
1
:
Display
F4-14
Menu Display
Control 2
*. *.
*. *. *. *. FF.
FE.
00000011
●
0 0 0 0 0 0 1 1
0
:
No Display
,
1
:
Display
F4-15
Monitoring
Reference
Selection
*
*
Estimated
Slip
Estimated
Speed
*
Sync-
Freq.
Inp.
Freq.
Outp.
Freq.
11111111
〇
0 0
1 1
1
1
1
1
0
:
Absolute Value
,
1
:
+/-