5. INSTALLATION INSTRUCTION
5.1 LOCATION REQUIREMENTS
5.1.1 ENVIRONMENT REQUIREMENTS
Cycraft is designed for
indoor use
and should never be installed outdoors.
Environment and facility requirements are as follows:
Installation location
Indoor use only
Ambient temperature
5 to 40 C
Humidity
10 to 70 % (no condensing)
Min. Entrance
dimensions
1540 mm (W) x 2100 mm (H)
Min. Ceiling Height
2400 mm (H)
Min. Footprint
(incl. Fence)
4050 mm (L) x 2900 mm (W)
Min. Floor Loading
310 kg/m
2
Cleanliness
Free of dust and debris
l
Never install the game machine outdoors
Also avoid the following locations even though they are indoors.
l
Near a leaky roof, close to any kind of dripping water, or any place with high
humidity that can condense
l
Close to an indoor pool or showers
l
Exposed to direct sunlight
l
Exposed to direct heat, such as close to a heater vent, or in a highly heated
room
l
Close to flammable or volatile chemicals, or dangerous materials
l
Avoid floors that slope(any slope more than 2 degrees)
l
Avoid strong vibrations
l
Avoid dusty locations
l
Avoid any location that does not allow enough space around the machine